Here are the results.
Date | Apr 30, 2018 |
First and Last Name | Captain Meneses |
Entry Type | STATION DEFECT |
Your entry | |
Mens Far right shower is clogged and shower head broke off. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Apr 30, 2018 |
First and Last Name | Captain Meneses |
Entry Type | STATION DEFECT |
Your entry | |
Mens Far right shower is clogged and shower head broke off. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Apr 30, 2018 |
First and Last Name | chris higgins |
Entry Type | STATION DEFECT |
Your entry | |
Fire Alarm is in trouble (dialer line 1fault), facilities was contacted and will send someone out tomorrow | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Apr 27, 2018 |
First and Last Name | chris higgins |
Entry Type | APPLIANCE DEFECT |
Your entry | |
Air chuck from RS715 driver side front compartment was found broken during morning check out. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Apr 27, 2018 |
First and Last Name | chris higgins |
Entry Type | GENERAL PASS ON |
Your entry | |
A water can and a dry chem. extinguisher was placed on RS715. Both were missing since switch over. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Apr 26, 2018 |
First and Last Name | Marvin Robinson |
Entry Type | GENERAL PASS ON |
Your entry | |
Two Husqvarna K970 saws came back and place on RS715. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Apr 26, 2018 |
First and Last Name | Captain Clemens |
Entry Type | APPARATUS DEFECT |
APPARATUS DEFECT | |
UNIT | PE715B (PIERCE) |
Your entry | |
E715B went to CMF electrical issues Pump would not go into gear A module was replaced and there are no more error codes | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Apr 26, 2018 |
First and Last Name | Captain Clemens |
Entry Type | GENERAL PASS ON |
Your entry | |
We are out of coffee | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Apr 25, 2018 |
First and Last Name | SMO |
Entry Type | GENERAL PASS ON |
Your entry | |
E715 LEFT, RS715 DRIVER, SPARE 3 SCBA RETURNED LOGGED BACK INTO SERVICE | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Apr 25, 2018 |
First and Last Name | Chief Ryman |
Entry Type | STATION DEFECT |
Your entry | |
The flashing on the edge of the roof over the training room is coming off over a significant distance. This is the area facing the generator. An FMOS defect has been submitted to include pictures. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Apr 24, 2018 |
First and Last Name | chris higgins |
Entry Type | SCBA DEFECT REPORT |
SCBA | |
Date sent out | Apr 24, 2018 |
SCBA designation ie (E715 Left, Spare 1) | A715 Driver |
Reason for unscheduled maintenance | hire powering the hud is lose and turning off |
Spare used? | Spare 1 |
Date | Apr 23, 2018 |
First and Last Name | Captain Clemens |
Entry Type | GENERAL PASS ON |
Your entry | |
SCBA compressor fixed | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Apr 21, 2018 |
First and Last Name | Mark Bulla |
Entry Type | APPARATUS DEFECT |
APPARATUS DEFECT | |
UNIT | RS715 (PIERCE) |
Your entry | |
Driver's side front halogen light out. Front halogen light out. Driver's side yellow marker/turn signal out. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Apr 21, 2018 |
First and Last Name | EMS Lt. T. G. Bulla |
Entry Type | GENERAL PASS ON |
Your entry | |
The Child Safety Seat remains missing from A715. Were we unable to recover it from the loaner Ambo returned? What is the next step to having it replaced. Thanks! | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Apr 20, 2018 |
First and Last Name | Roger Hohman |
Entry Type | GENERAL PASS ON |
Your entry | |
100' Section of 4" removed from E715-B and placed O.O.S | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Apr 18, 2018 |
First and Last Name | Captain Meneses |
Entry Type | GENERAL PASS ON |
Your entry | |
PE715 MDC power adaptor was written up. A temporary fix was made by Lt. Houck. Power to MDC is fine for now. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Apr 18, 2018 |
First and Last Name | chris higgins |
Entry Type | GENERAL PASS ON |
Your entry | |
Pry bar was placed back on T715, it was left on RT1. Still missing a pick head axe and water shut off | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Apr 18, 2018 |
First and Last Name | chris higgins |
Entry Type | SCBA DEFECT REPORT |
SCBA | |
Date sent out | Apr 18, 2018 |
SCBA designation ie (E715 Left, Spare 1) | spare 3 |
Reason for unscheduled maintenance | flow testing |
Spare used? | N/A |
Date | Apr 18, 2018 |
First and Last Name | chris higgins |
Entry Type | SCBA DEFECT REPORT |
SCBA | |
Date sent out | Apr 18, 2018 |
SCBA designation ie (E715 Left, Spare 1) | e715 left |
Reason for unscheduled maintenance | flow testing |
Spare used? | none |
Date | Apr 18, 2018 |
First and Last Name | chris higgins |
Entry Type | SCBA DEFECT REPORT |
SCBA | |
Date sent out | Apr 18, 2018 |
SCBA designation ie (E715 Left, Spare 1) | rs715 driver |
Reason for unscheduled maintenance | flow testing and waist strap buckle |
Spare used? | Spare 4 |
Date | Apr 17, 2018 |
First and Last Name | Captain Clemens |
Entry Type | GENERAL PASS ON |
Your entry | |
Truck MDC has a loaner....ours was showing a blue screen | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Apr 17, 2018 |
First and Last Name | Captain Clemens |
Entry Type | GENERAL PASS ON |
Your entry | |
Fikar wuz here today and said he will come back to fix the SCBA compressor when the parts come in | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Apr 15, 2018 |
First and Last Name | chris higgins |
Entry Type | STATION GENERATOR CHECK |
STATION GENERATOR CHECK | |
Fuel level | 99% |
Coolant temp | 124 |
Run hrs | 235 |
Oil Ok? | Yes |
Visual inspection ok? | Yes |
Defect report written? | No |
Date | Apr 14, 2018 |
First and Last Name | Chief Ryman |
Entry Type | APPARATUS DEFECT |
APPARATUS DEFECT | |
UNIT | RS715 (PIERCE) |
Your entry | |
The leaking hose was located at the top of the motor coming directly off of the coolant reservoir. Hose replaced. 5 gallons of coolant utilized. Cmf updated via email. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Apr 14, 2018 |
First and Last Name | Mark Bulla |
Entry Type | APPARATUS DEFECT |
APPARATUS DEFECT | |
UNIT | RS715 (PIERCE) |
Your entry | |
Check engine, stop engine and low coolant alarms went off after responding to a call. Engine temperature was running around 210 while idling, and would drop to ~180 while driving. Previous squad driver said that the same thing happened earlier in the day. They tilted the cab and added about 1 gallon of coolant. I had driven the unit non-emergent earlier in the evening with no problems. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Apr 14, 2018 |
First and Last Name | Captain Clemens |
Entry Type | GENERAL PASS ON |
Your entry | |
SCBA Compressor is not filling up the storage it ran for an hour with no change | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Apr 14, 2018 |
First and Last Name | Captain Clemens |
Entry Type | APPLIANCE DEFECT |
Your entry | |
Hurst air tools regulator for Air Bags One of them is missing a rubber O-ring It's in the Captain's Office | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Apr 14, 2018 |
First and Last Name | Mark Bulla |
Entry Type | APPARATUS DEFECT |
APPARATUS DEFECT | |
UNIT | B715 |
Your entry | |
The pull rope on the pump is broken. The handle and half of the broken cord was placed in the shop by FF Mokosso. The electric pump start works fine. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Apr 12, 2018 |
First and Last Name | Willie Owens |
Entry Type | STATION DEFECT |
Your entry | |
Washing machine drain hose leaking where the hose goes into the drain in the wall. This is for the main washer next to locker room. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Apr 12, 2018 |
First and Last Name | Willie Owens |
Entry Type | STATION DEFECT |
Your entry | |
Washing machine drain hose leaking where the hose goes into the drain in the wall. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Apr 12, 2018 |
First and Last Name | chris higgins |
Entry Type | GENERAL PASS ON |
Your entry | |
T715 is missing a pick head axe and the pry bar possibly left on rt1 | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Apr 09, 2018 |
First and Last Name | chris higgins |
Entry Type | GENERAL PASS ON |
Your entry | |
RRS1 was picked up by R1, RS715 oos | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Apr 09, 2018 |
First and Last Name | Emmett Winston |
Entry Type | APPARATUS DEFECT |
APPARATUS DEFECT | |
UNIT | B715 |
Your entry | |
Brush truck is down to a half a tank of fuel. We found a fuel key however it's the red one which is the supervisor key. We were unable to refuel after the brush fires. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Apr 09, 2018 |
First and Last Name | Captain Clemens |
Entry Type | APPARATUS DEFECT |
APPARATUS DEFECT | |
UNIT | T715 |
Your entry | |
T715 had to be towed to CMF in the evening from a brush fire headlights were extremely dim Radios would not turn on Check engine light came on the dashboard The transmission would not go into "drive" We shut the engine down and it would not start again Possible alternator or charging issue All equip taken of Truck and placed on Reserve except ladders There are a few items on the floor behind the truck in the engine room not placed on the truck. Running RT-1 from station 6 | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Apr 07, 2018 |
First and Last Name | BVFD President T. G. Bulla |
Entry Type | GENERAL PASS ON |
Your entry | |
Commemorative decal applied to Driver Side vent window of Ambulance 715 in honor of one year anniversary of loss of Master Firefighter Rick Gentilcore at FS15 on 4/7/17. Approved by Chief Goldstein. |
Date | Apr 06, 2018 |
First and Last Name | chris higgins |
Entry Type | GENERAL PASS ON |
Your entry | |
T715 driver side front duals were replaced with new tires. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Apr 05, 2018 |
First and Last Name | Captain Clemens |
Entry Type | GENERAL PASS ON |
Your entry | |
RRS1 running as RS715 | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Apr 05, 2018 |
First and Last Name | Captain Clemens |
Entry Type | GENERAL PASS ON |
Your entry | |
Benjamin office supply delivered Invoice in box | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Apr 05, 2018 |
First and Last Name | Captain Clemens |
Entry Type | STATION DEFECT |
Your entry | |
Fire alarm system made some sort of alarm noise similar to trouble alarm not fire alarm when I checked panel it says "Detector Service" in bunkroom This is not an emergency repair The system is still operational My guess is we have a bad detector in the bunkroom There are other detectors in bunkroom | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Apr 04, 2018 |
First and Last Name | President T. G. Bulla |
Entry Type | GENERAL PASS ON |
Your entry | |
DGS sent a locksmith to change the combination to all cipher locks this afternoon. Please caution your personnel not to release the new combination to anyone they are not 100% sure is a current BVFD Member. Butch Charlton is no longer affiliated with the BVFD or MCFRS and should not be provided the new code. The entry door closest to the admin offices requires an access card currently, as they could not make the cipher lock function after attempting to change the combination. We request your heightened assistance in keeping the station doors secure for the next few weeks following a Member termination. Thank you. |
Date | Apr 03, 2018 |
First and Last Name | President T. G. Bulla |
Entry Type | GENERAL PASS ON |
Your entry | |
Following action by the Board of Directors to terminate a Member this evening, a formal request was submitted to have the combination of FS15 cipher locks changed tomorrow. It is a safety measure to both decrease the chance of inappropriate station entry and to offer some reassurance to the Member(s) who had been bullied and intimidated by the terminated Member. In addition, the periodic changing of the combination is warranted for general station security. We hope facilities will act on the request on Wednesday. |
Date | Apr 03, 2018 |
First and Last Name | Chief Ryman |
Entry Type | GENERAL PASS ON |
Your entry | |
Please disregard the earlier post in reference to the squad. The mechanic has now advised that their is fuel in the coolant and the unit will need to go OOS in the morning. It will then be moved to Manassas for the work. They are unsure of the movement plan at this point and will determine in the morning. I don't have specific ETA on it coming back however they don't seem to think its a terribly involved repair. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Apr 03, 2018 |
First and Last Name | Chief Ryman |
Entry Type | GENERAL PASS ON |
Your entry | |
The rescue squad is being put back together and will remain in service overnight, however the road tech from Western Branch will be back around 0700 tomorrow morning with parts to replace injectors. It will need to go OOS at that point until repaired. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Apr 02, 2018 |
First and Last Name | Chief Ryman |
Entry Type | APPARATUS DEFECT |
APPARATUS DEFECT | |
UNIT | RS715 (PIERCE) |
Your entry | |
This defect was submitted today at the request from CMF as there was no defect in the system for this issue. The unit is starting very rough after sitting for more than 10 or so hours. It will only initially partially turn over, then turn over fully but start slowly and rev up quickly and loudly (making a struggling type sound) producing large quantity of white smoke from exhaust with substantial fuel odor. The unit is producing a much stronger fuel odor than usual from the grill area at all times in general. This started on Thursday or Friday of last week. There are no lights or alarms during this. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |