Here are the results.
Date | Jul 30, 2019 |
First and Last Name | chris higgins |
Entry Type | GENERAL PASS ON |
Your entry | |
Sta. 15 spare medium face piece was swopped out at the SCBA shop | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Jul 30, 2019 |
First and Last Name | chris higgins |
Entry Type | GENERAL PASS ON |
Your entry | |
Sta. 15 spare medium face piece was swopped out at the SCBA shop | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Jul 30, 2019 |
First and Last Name | Chris Higgins |
Entry Type | GENERAL PASS ON |
Your entry | |
Lt Houck took 5 portable battery's that were bad, he will replace them tomorrow | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Jul 30, 2019 |
First and Last Name | chris higgins |
Entry Type | GENERAL PASS ON |
Your entry | |
The two pelican lights were dropped off at small tools no replacement were available, a section of 1 3/4 was switched out, and the RS715 TIC was found broken this morning. A loaner TIC was placed on the sq | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Jul 29, 2019 |
First and Last Name | Marvin Robinson |
Entry Type | APPLIANCE DEFECT |
Your entry | |
2 Pelican lights on Truck 715 not working after attempting recharge. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Jul 29, 2019 |
First and Last Name | Lyons |
Entry Type | APPARATUS DEFECT |
APPARATUS DEFECT | |
UNIT | RS715 (PIERCE) |
Your entry | |
Air line from compressor is stretched across the floor to the squad. it didn't run any calls dayside and the front air tanks bled from 100psi at 1000am to absolute zero psi at 1700. Air leak was written up previously. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Jul 29, 2019 |
First and Last Name | Matt Adams |
Entry Type | GENERAL PASS ON |
Your entry | |
Laminated apparatus driver PAGS for the engine, truck and rescue squad are in three separate folders located in the watch room. Please place back after training/use. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Jul 27, 2019 |
First and Last Name | Chief Ryman |
Entry Type | APPARATUS DEFECT |
APPARATUS DEFECT | |
UNIT | RS715 (PIERCE) |
Your entry | |
The petrogen torch is now secured in the walk-in of the squad and should be able to mainain an upright position. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Jul 26, 2019 |
First and Last Name | Matt Adams |
Entry Type | GENERAL PASS ON |
Your entry | |
SCBA shop fixed the fill station fill control, as well as completed routine service on the air compressor. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Jul 26, 2019 |
First and Last Name | Brian Jordan |
Entry Type | GENERAL PASS ON |
Your entry | |
RS715 Medium Pressure air bag returned from repairs, placed in back of walk in. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
FYI-
The PSTA will be coming to borrow a fan today for an extended period to support metro in-service training.
Date | Jul 25, 2019 |
First and Last Name | Robert Marsh |
Entry Type | GENERAL PASS ON |
Your entry | |
Two Laminated "Cheat Sheets" have been placed on the Engine - Truck and Rescue Squad. They are each labeled to the apparatus they go with. One is a "24" cheat sheet and the other is a 1st Due Cheat Sheet. If you do not care for them please place them in the Checkout Book for others to grab when they want. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Jul 24, 2019 |
First and Last Name | Willie Owens |
Entry Type | APPARATUS DEFECT |
APPARATUS DEFECT | |
UNIT | OTHER |
OTHER UNIT | |
SPECIFY UNIT ID | RE1 |
Your entry | |
CAFS compressor and Transmission thermostat OOS | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Jul 24, 2019 |
First and Last Name | Willie O |
Entry Type | GENERAL PASS ON |
Your entry | |
E715 placed OOS for DOT/PM. Switched into RE1 The only thing that RE1 had on it was hose and hard sleeves Complete inventory including ALL nozzles and short shots belong to E715 We switched over the 300'- 1 3/4" line and placed the 2 1/2' hose belonging to RE1 on the shelf in Engine Room. |
Date | Jul 24, 2019 |
First and Last Name | Chris Higgins |
Entry Type | GENERAL PASS ON |
Your entry | |
Missing SCBA from T715 (C2) was found on E715B, pack was put back on T715 | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Jul 24, 2019 |
First and Last Name | chris higgins |
Entry Type | GENERAL PASS ON |
Your entry | |
SCBA fill station is OOS, SCBA shop was contacted and will be out of Friday to fix. 20 cylinders were taken to station 16 and filled. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Jul 24, 2019 |
First and Last Name | chris higgins |
Entry Type | GENERAL PASS ON |
Your entry | |
10 bags of absorbent picked up at small tools, section of 2", 1 3/4" and 3" was also picked up | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Jul 22, 2019 |
First and Last Name | Robert Marsh |
Entry Type | APPARATUS DEFECT |
APPARATUS DEFECT | |
UNIT | RS715 (PIERCE) |
Your entry | |
RS715 Rear Portable Winch Connection is damaged and does not properly protect the electrical connection. This causes rear portable winch to work intermittently. The other 2 connections on the Officers and Drivers side work fine. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Jul 22, 2019 |
First and Last Name | Robert Marsh |
Entry Type | APPARATUS DEFECT |
APPARATUS DEFECT | |
UNIT | RS715 (PIERCE) |
Your entry | |
The Rescue Squad drops out of High Idle after roughly 15 Minutes of being in High Idle with the Generator PTO and Tool PTO engaged. At Hi Idle the Rescue Squad runs at 1200 RPM's. When not in Hi Idle it only runs at 600 RPMs. It is assumed that 600 RPMS will not adequality power the Amkus Ultimate System. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Jul 21, 2019 |
First and Last Name | Willie O |
Entry Type | APPARATUS DEFECT |
APPARATUS DEFECT | |
UNIT | RS715 (PIERCE) |
Your entry | |
Squad has slow air leak. Does not leak during brake test but takes a min to rebuild pressure. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Jul 21, 2019 |
First and Last Name | John Russo |
Entry Type | GENERAL PASS ON |
Your entry | |
M715 glucometer misplaced. Attempting to locate. RS715 glucometer moved to M715 red bag in mean time. OIC of squad notified. |
Date | Jul 21, 2019 |
First and Last Name | Josh Mister |
Entry Type | GENERAL PASS ON |
Your entry | |
Truck tic sent to small tools because it will not turn on. 2nd tic from squad placed on truck. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Jul 21, 2019 |
First and Last Name | Brett Carter |
Entry Type | STATION GENERATOR CHECK |
STATION GENERATOR CHECK | |
Fuel level | 88 |
Coolant temp | 99 |
Run hrs | 267 |
Oil Ok? | Yes |
Visual inspection ok? | Yes |
Defect report written? | No |
Date | Jul 21, 2019 |
First and Last Name | Marvin Robinson |
Entry Type | APPLIANCE DEFECT |
Your entry | |
Found a hole in 50ft section of yellow 2inch hose after fire. Hose has been placed out of service. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Jul 20, 2019 |
First and Last Name | Arnold Massicott |
Entry Type | GENERAL PASS ON |
Your entry | |
EPCR on M715 is OOS. M715 is now using the spare that was located by the battery chargers. EMS DO was notified and said a new one would be delivered today or tomorrow. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Jul 18, 2019 |
First and Last Name | Captain Clemens |
Entry Type | APPARATUS DEFECT |
APPARATUS DEFECT | |
UNIT | A715 |
Your entry | |
RA3 oos air conditioning patient compartment RA7 picked up from Sta 21 | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Jul 18, 2019 |
First and Last Name | KYLE GALLAGHER |
Entry Type | APPARATUS DEFECT |
APPARATUS DEFECT | |
UNIT | A715 |
Your entry | |
AC in passenger compartment does not cool. Fan seems to work but air is basically outside temp | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Jul 17, 2019 |
First and Last Name | Captain Clemens |
Entry Type | GENERAL PASS ON |
Your entry | |
RA3 (A715) Russell Hartung delivered a DC charger now MDC back in service | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Jul 17, 2019 |
First and Last Name | lyons |
Entry Type | GENERAL PASS ON |
Your entry | |
ambo mdc not working. ticket written | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Jul 17, 2019 |
First and Last Name | Captain Clemens |
Entry Type | GENERAL PASS ON |
Your entry | |
Reserve Ambulance 3 (A715) The MDC works but does not charge Believe the wire from the charging cable is shorting out | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | telecomm request |
Date | Jul 17, 2019 |
First and Last Name | Captain Clemens |
Entry Type | STATION GENERATOR CHECK |
STATION GENERATOR CHECK | |
Fuel level | 87 |
Coolant temp | 100 |
Run hrs | 267 |
Oil Ok? | Yes |
Visual inspection ok? | Yes |
Defect report written? | No |
Date | Jul 15, 2019 |
First and Last Name | Lyons |
Entry Type | APPARATUS DEFECT |
APPARATUS DEFECT | |
UNIT | RS715 (PIERCE) |
Your entry | |
Check engine and trans comm loss occurring every time the squad runs down the road. When it happens, the Telma and engine brake don't operate and the transmission limits you to 4th gear similar to what the Crimson does without the mode button pushed. It resets when the rig is turned off and on again. Written up | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Jul 13, 2019 |
First and Last Name | Chief Ryman |
Entry Type | GENERAL PASS ON |
Your entry | |
The Petrogen torch has been placed in service on RS715. It is located behind the RS3 and RS4 positions. There is one extra oxygen tank in the first netted area on the right. The process for oxygen replacement remains the same, please notify me and I'll have an empty swapped out. It will remain this way until small tools finalizes a contract update. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Jul 12, 2019 |
First and Last Name | Lyons |
Entry Type | APPARATUS DEFECT |
APPARATUS DEFECT | |
UNIT | T715 |
Your entry | |
Truck had a hydraulic leak around the jack overrides. Went to CMF and it was fixed. The jake brake has worked continuously (contrary to a previous write up) and the Telma magically started working again when we left CMF with no work done to it. ABS light continues. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Jul 11, 2019 |
First and Last Name | chris higgins |
Entry Type | STATION DEFECT |
Your entry | |
Alpha radio is going in and out, the audio sounds like it is under water and can not hear anything. It will do that for accouple min. then go back to normal. The Bravo/Pg scanner is working normal. |
Date | Jul 11, 2019 |
First and Last Name | Matt Adams |
Entry Type | GENERAL PASS ON |
Your entry | |
Engine Driver, Truck right and rescue squad right SCBAs back in service. Spares placed back in SCBA room. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Jul 11, 2019 |
First and Last Name | Matt Adams |
Entry Type | STATION DEFECT |
Your entry | |
Station hot water heater is OOS. Facilities is obtaining the part needed. Will be back in station to complete the repair tonight or Friday A-shift. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Jul 11, 2019 |
First and Last Name | Matt Adams |
Entry Type | APPARATUS DEFECT |
APPARATUS DEFECT | |
UNIT | PE715 (CRIMSON) |
Your entry | |
Drivers side MIV electronic switch is operating intermittently. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Jul 09, 2019 |
First and Last Name | chris higgins |
Entry Type | GENERAL PASS ON |
Your entry | |
Paratech was out and fixed the hydra-fusion lifting cylinder | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Jul 09, 2019 |
First and Last Name | chris higgins |
Entry Type | GENERAL PASS ON |
Your entry | |
50' section of 3" hose off of the rack blow a hole while doing a drill section was placed by the shop. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Jul 08, 2019 |
First and Last Name | Brian Jordan |
Entry Type | GENERAL PASS ON |
Your entry | |
A715 dropped off at CMF for coolant leak, RA15 running as A715 Hydra rams picked up from CMF, loaner picked up by courier | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Jul 08, 2019 |
First and Last Name | lyons |
Entry Type | APPARATUS DEFECT |
APPARATUS DEFECT | |
UNIT | RS715 (PIERCE) |
Your entry | |
Front tires approaching replacement time. Written up. Cab flood lights not working. Written up. Check engine light and ABS light continues. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Jul 07, 2019 |
First and Last Name | Robert Marsh |
Entry Type | GENERAL PASS ON |
Your entry | |
Stanley System Tire fixed in house. Disregard previous write up. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Jul 07, 2019 |
First and Last Name | Robert Marsh |
Entry Type | GENERAL PASS ON |
Your entry | |
Stanley System Tire Flat. Stanley System still works obviously but will be a pain in the ass to drag around. Hydrafusion Strut that leaks was removed and placed on blue couch. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Jul 07, 2019 |
First and Last Name | Robert Marsh |
Entry Type | GENERAL PASS ON |
Your entry | |
Rescue Squad Strut Inventory: Left (2) V tips connected to 48" struts Left (2) Chain tips connected to other 48" Struts Left (2) Pointy Tips in box that has (4) base plates in compartment with struts We figured this gave you the greatest flexibility with what you may use. Please let B shift and others know if this doesn't work for you so we can all come up with a program. Thanks | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Jul 06, 2019 |
First and Last Name | chris higgins |
Entry Type | APPARATUS DEFECT |
APPARATUS DEFECT | |
UNIT | RS715 (PIERCE) |
Your entry | |
RS715 has gotten a check eng light, loss trans com, and loss eng com, plus a ABS light three separate times today after having the tool pto on today. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Jul 06, 2019 |
First and Last Name | Gallagher |
Entry Type | APPARATUS DEFECT |
APPARATUS DEFECT | |
UNIT | B715 |
Your entry | |
Rear driver's side tire found low at 20 PSI. It has been filled but should be monitored. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Jul 06, 2019 |
First and Last Name | chris higgins |
Entry Type | GENERAL PASS ON |
Your entry | |
one of the hydra fusion lifting cylinders has a hydraulic leak where the swivel connection going to the cylinder. Ryman said he will handle | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Jul 06, 2019 |
First and Last Name | Benjamin Brighton |
Entry Type | APPARATUS DEFECT |
APPARATUS DEFECT | |
UNIT | PE715 (CRIMSON) |
Your entry | |
Fuel Gauge read Empty in morning, took 4.1 gal diesel Fuel Gauge read Full in evening, took 8.1 gal diesel | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Jul 06, 2019 |
First and Last Name | Luis Ruiz-Flores |
Entry Type | APPARATUS DEFECT |
APPARATUS DEFECT | |
UNIT | T715 |
Your entry | |
Engine brake not activating while driving on T715. Officer window also not working | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Jul 06, 2019 |
First and Last Name | Luis Ruiz-Flores |
Entry Type | APPARATUS DEFECT |
APPARATUS DEFECT | |
UNIT | T715 |
Your entry | |
Telma retarder not activating on T715 | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Jul 06, 2019 |
First and Last Name | Luis Ruiz-Flores |
Entry Type | APPARATUS DEFECT |
APPARATUS DEFECT | |
UNIT | T715 |
Your entry | |
ABS light on T715 stays on while driving. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Jul 06, 2019 |
First and Last Name | chris higgins |
Entry Type | GENERAL PASS ON |
Your entry | |
3 head sets were sent out for repair. 1 truck and 1 eng. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Thank you Dish!
youtu.be In episode 52, Steve and Alex are joined by guest David Kottler of Mamma Lucia at Stained Glass Pub in Glenmont to discuss: - Bennigans leaves MoCo once agai... |
Date | Jul 04, 2019 |
First and Last Name | Chief Ryman |
Entry Type | GENERAL PASS ON |
Your entry | |
The initial paratech inventory was placed in service on the squad today. The list is as follows: Qty Item 4 55"-88" acme thread strut 2 37"-58" acme thread strut 2 25'-36' acme thread strut 2 36" strut extension 2 24" strut extension 2 10" strut extension 2 Hydra-Fusion 10" lift 2 Hydra-Fusion pumps 8 12" hinged bases w/ anchor ring 6 Multi-base tips 6 V tips 2 Offset Cone tips 4 strut converters 4 4" X 4" channel tip 2 6" X 6" channel tip 4 3" X 4" angle tip 1 Tripod head 2 3 shore column plate The components are arranged as similar to the ART shores as possible with some minor changes at this point. There are a few additional items that are yet to arrive as well. I anticipate small re-arrangements over the next few days as we tune in the best scenario. The ART shores are on the couches behind E715B. They will be relocated over the weekend. | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Jul 03, 2019 |
First and Last Name | chris higgins |
Entry Type | APPARATUS DEFECT |
APPARATUS DEFECT | |
UNIT | RS715 (PIERCE) |
Your entry | |
There was a major air leak coming from the top of the air compressor on RS715. CMF replaced the part | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Jul 03, 2019 |
First and Last Name | Brian Jordan |
Entry Type | APPARATUS DEFECT |
APPARATUS DEFECT | |
UNIT | PE715 (CRIMSON) |
Your entry | |
E715's rear cab A/C does not work | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
Date | Jul 03, 2019 |
First and Last Name | Brian Jordan |
Entry Type | APPARATUS DEFECT |
APPARATUS DEFECT | |
UNIT | PE715 (CRIMSON) |
Your entry | |
PE715 had both front tires replaced at RICE tires on 7/3/19 | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Jul 02, 2019 |
First and Last Name | Captain Clemens |
Entry Type | GENERAL PASS ON |
Your entry | |
RS715 is back RRS1 at CMF | |
IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
Date | Jul 01, 2019 |
First and Last Name | Mark Grant |
Entry Type | GENERAL PASS ON |
Your entry | |
Medic unit inventory is being updated to current County standard (not yet complete). Labeling is being provided to help keep it organized. Please check the unit and familiarize yourself with the changes. |