Wednesday, December 4, 2019

Defects- Various apparatus

The following has been written up while the form entry option is down: 

This is to inform you that Christian Mautz reporting from station 15 has submitted the following defect report for Stock #2-16-6387.

Defect Description: Drivers side front set of duels, inner tire tread depth 5 3/2nds. Needs replaced soon.

This is to inform you that Christian Mautz reporting from station 15 has submitted the following defect report for Stock #2-16-6387.

Defect Description: Roof mounted floodlights do not work. both sides will not come on.


This is to inform you that Christian Mautz reporting from station 15 has submitted the following defect report for Stock #2-16-6387.

Defect Description: auxiliary coolant reservoir cap is cracked. No leaks at this time.


This is to inform you that Christian Mautz reporting from station 15 has submitted the following defect report for Stock #2-16-6387.

Defect Description: engine air filter looks dirty. No codes but needs replaced soon.


This is to inform you that Christian Mautz reporting from station 15 has submitted the following defect report for Stock #2-16-6387.

Defect Description: Roto-ray does not spin when lights are on and in drive.


This is to inform you that Christian Mautz reporting from station 15 has submitted the following defect report for Stock #2-16-6387.

Defect Description: Engine compartment heat insulation is falling off of body. Found piece of foam being sucked into fan shroud. Multiple panels missing.


This is to inform you that Christopher Higgins reporting from station 15 has submitted the following defect report for Stock #4-05-4535.

Defect Description: RS715 has slow air leak. Air is leaking to 70 psi in a few hours. No leak detected during brake test but takes a min or 2 to rebuild. I found the leak coming from a coupling on the driver side under the cab. The pictures were sent to via email since it would not attach to reporting system


This is to inform you that Marvin Robinson reporting from station 15 has submitted the following defect report for Stock #4-05-4535.

Defect Description: FOUND A CRACK IN THE OFFICERS SIDE WINDSHIELD. NEEDS TO BE REPAIRED OR REPLACED


This is to inform you that Benjamin Brighton reporting from station 15 has submitted the following defect report for Stock #1-08-7594.

Defect Description: Officer #1 discharge not closing properly every time. Occasionally has to be manually opened and closed to prevent leakage.


This is to inform you that Benjamin Brighton reporting from station 15 has submitted the following defect report for Stock #1-08-7594.

Defect Description: Officer #2 discharge status lights on pump panel not indicating properly every time.


This is to inform you that Benjamin Brighton reporting from station 15 has submitted the following defect report for Stock #1-08-7594.

Defect Description: Garden hose gasket found in CAFS strainer this morning.


This is to inform you that Matthew Lyons reporting from station 15 has submitted the following defect report for Stock #1-08-9038.

Defect Description: Officer's side high flow discharge #1 has a significant leak at the butterfly valve o-ring. After several attempts to slow the leak, it was noticed that the tank water level had dropped several inches with the tank-to-pump closed, leading us to believe the tank-to-pump valve is not closing properly. The unit is currently running but with a garden hose trickle filling the tank.


THis list is up to date as of 2030 hours today. 


Michael Ryman
Fire Chief
Burtonsville VFD
13900 Old Columbia Pike
Silver Spring, Md 20904
Cell: 570-766-9054

No comments: