Monday, December 4, 2017

Dec 04, 2017 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateDec 04, 2017
First and Last Namechris higgins
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITOTHER
OTHER UNIT
SPECIFY UNIT ID RRS1
Your entry
RRS1 was taken to CMF today for the back door latch, while at CMF a mechanic was injured when equipment fell out of a compartment. CMF deemed the SQ unsafe and could not leave CMF and all equipment must stay on the RS until investigated.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Dec 04, 2017 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateDec 04, 2017
First and Last Namechris higgins
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITT715
Your entry
T715 was placed OOS for a coolant leak, O ring on top of the radiator is bad. RAT 2 is running as T715, all equipment was switched over except ladders and pry bar.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Sunday, December 3, 2017

Dec 03, 2017 - STATION GENERATOR CHECK

Your form has a new entry.

Here are the results.

DateDec 03, 2017
First and Last NameCaptain Clemens
Entry TypeSTATION GENERATOR CHECK
STATION GENERATOR CHECK
Fuel level99%
Coolant temp115
Run hrsn/a
Oil Ok?Yes
Visual inspection ok?Yes
Defect report written?No

Dec 03, 2017 - SCBA DEFECT REPORT

Your form has a new entry.

Here are the results.

DateDec 02, 2017
First and Last NameAFC Ryman
Entry TypeSCBA DEFECT REPORT
SCBA
Date sent outDec 03, 2017
SCBA designation ie (E715 Left, Spare 1)T715 R
Reason for unscheduled maintenanceRegulator in pieces, slammed in door
Spare used?Spare 3

Dec 03, 2017 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateDec 02, 2017
First and Last NameAFC Ryman
Entry TypeGENERAL PASS ON
Your entry
A hook was installed on the wall of the T3 position as another SCBA regulator was damaged yesterday following being slammed in the door.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Saturday, December 2, 2017

Dec 02, 2017 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateDec 02, 2017
First and Last NameScott Cook
Entry TypeGENERAL PASS ON
Your entry
There is a hydrant near 14100 Castle Blvd. This hydrant is all white in color and has not had the proper bonnet top since I have been here. I have contacted WSSC a few times to no avail. Following FCGO 17-13, Fire Safety Code procedures, I filed a complaint with code.

We'll see what happens...
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Dec 02, 2017 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateDec 02, 2017
First and Last NameM. Bulla
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITOTHER
OTHER UNIT
SPECIFY UNIT ID RRS1
Your entry
Bottom latch for right-most changeable number in the rear of the squad is broken.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Dec 02, 2017 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateDec 02, 2017
First and Last NameM. Bulla
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITOTHER
OTHER UNIT
SPECIFY UNIT ID RRS1
Your entry
Bottom part of latch for walk-in door not in the correct position, making it difficult to correctly latch the door. The piece is inside the door and may be bent - it's not fixable without taking off the inside door panel.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Dec 02, 2017 - STATION DEFECT

Your form has a new entry.

Here are the results.

DateDec 02, 2017
First and Last NameM. Charlton
Entry TypeSTATION DEFECT
Your entry
Station alerting system visual indicator in the day room did not illuminate for RS715 alert for incident #17-006007877
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Friday, December 1, 2017

Dec 01, 2017 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateDec 01, 2017
First and Last NameAFC Ryman
Entry TypeGENERAL PASS ON
Your entry
Two representatives from CRW were at the station all day today and they think they found the issue with HVAC. There are 13 air handlers all together. They checked the wiring on 5, of which four out of the five were all wired (routed) incorrectly . Tyler the Project Manager is aware of everything and Siemens will be here on Monday to redo the wiring and check the remaining handlers to ensure they are also wired correctly.

He said that this only became an issue with the recent weather since every area is trying to heat and cool at different times exposing the improperly routed wiring. (For example, my thermostat might have controlled the kitchen). It was not an issue in the summer because all areas simply needed to be cooled.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Dec 01, 2017 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateDec 01, 2017
First and Last Namechris higgins
Entry TypeGENERAL PASS ON
Your entry
M2 radio mic oos switched radios with bc701 using loaner 6
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Dec 01, 2017 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateDec 01, 2017
First and Last NameAFC Ryman
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITRS715 (PIERCE)
Your entry
The actual RS715 arrived at Pierce today intact.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Dec 01, 2017 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateDec 01, 2017
First and Last Namechris higgins
Entry TypeGENERAL PASS ON
Your entry
The two bottle jacks and the floor jack were returned today. The only thing missing is the top section of the handle for the floor jack. Small tools was notified and will send a handle out.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES