Here are the results.
| Date | Jul 10, 2018 |
| First and Last Name | J. Keefer |
| Entry Type | GENERAL PASS ON |
| Your entry | |
| t715 multi gas meter, calibration failed. meter shop was closed when we tried to get it repaired. | |
| IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
| Date | Jul 10, 2018 |
| First and Last Name | J. Keefer |
| Entry Type | GENERAL PASS ON |
| Your entry | |
| t715 multi gas meter, calibration failed. meter shop was closed when we tried to get it repaired. | |
| IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
| Date | Jul 10, 2018 |
| First and Last Name | J. Keefer |
| Entry Type | GENERAL PASS ON |
| Your entry | |
| Husqvarna circular saw picked up from small tools and placed back on rs715 | |
| IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
| Date | Jul 09, 2018 |
| First and Last Name | Chief Ryman |
| Entry Type | GENERAL PASS ON |
| Your entry | |
| First Due Custom Solutions (The person that made the mudflap for the back of the squad.) will be in at some point this week to do some repairs to the flap. | |
| IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
| Date | Jul 08, 2018 |
| First and Last Name | Willie Owens |
| Entry Type | GENERAL PASS ON |
| Your entry | |
| Broken window hatch glass on RS is supposed to be replaced by Monday or Tuesday. | |
| Date | Jul 08, 2018 |
| First and Last Name | Willie Owens |
| Entry Type | GENERAL PASS ON |
| Your entry | |
| RS715 missing the lower half of floor jack lever and tarps. Not sure if these items were left on RRS1. Tarps were removed from storage and placed on RS in mean time. | |
| Date | Jul 07, 2018 |
| First and Last Name | Chief Ryman |
| Entry Type | GENERAL PASS ON |
| Your entry | |
| All hooks on T715 were repainted with the exception of the 8' on the aerial. The majority of the hooks were also rewrapped, however about 3 remain. They'll be completed after additional wrap is acquired. | |
| Date | Jul 06, 2018 |
| First and Last Name | Jeffrey Weber |
| Entry Type | APPARATUS DEFECT |
| APPARATUS DEFECT | |
| UNIT | RS715 (PIERCE) |
| Your entry | |
| RS715 roof hatch was damaged while backing into station. Broken glass was removed. Safety 700 and Batt 1 were notified. | |
| IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
| Date | Jul 06, 2018 |
| First and Last Name | Jeffrey Weber |
| Entry Type | GENERAL PASS ON |
| Your entry | |
| HVAC in Main bunk room was successfully reset and is now functioning properly. Training Room HVAC was also looked at, but no determination was made. | |
| IF DEFECT, WAS A REPAIR REQUEST MADE? | NO |
| Date | Jul 05, 2018 |
| First and Last Name | Capt. Meneses |
| Entry Type | GENERAL PASS ON |
| Your entry | |
| EMS Supplies were received and put away | |
| Date | Jul 05, 2018 |
| First and Last Name | Capt. Meneses |
| Entry Type | STATION DEFECT |
| Your entry | |
| -AC in Main Bunk room doesn't seem to be working -Poison Ivy near Dumpster -Blue lockers have no combos that work and follow up to initial request was submitted. | |
| IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
| Date | Jul 02, 2018 |
| First and Last Name | Josh DeVries |
| Entry Type | SCBA DEFECT REPORT |
| SCBA | |
| Date sent out | Jul 02, 2018 |
| SCBA designation ie (E715 Left, Spare 1) | T715R |
| Reason for unscheduled maintenance | REGULATOR BROKE IN HALF |
| Spare used? | Spare 4 |
| Date | Jul 01, 2018 |
| First and Last Name | Chief Ryman |
| Entry Type | STATION DEFECT |
| Your entry | |
| Training room HVAC found not working again this morning. Facilities was called and sent a tech out. Unsure of further disposition of this issue. The control matter as a whole for this area has been pushed higher up the chain for assistance. | |
| IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |
| Date | Jul 01, 2018 |
| First and Last Name | Captain Clemens |
| Entry Type | GENERAL PASS ON |
| Your entry | |
| A715 EMeds not repsonding properly EMS704 coming by to drop off new EPCR | |
| IF DEFECT, WAS A REPAIR REQUEST MADE? | YES |