Sunday, December 31, 2017

Dec 31, 2017 - STATION GENERATOR CHECK

Your form has a new entry.

Here are the results.

DateDec 31, 2017
First and Last NameChazz Smith
Entry TypeSTATION GENERATOR CHECK
STATION GENERATOR CHECK
Fuel level99%
Coolant temp100
Run hrs225
Oil Ok?Yes
Visual inspection ok?Yes
If any issues found write in hereN/A
Defect report written?No

Friday, December 29, 2017

Dec 29, 2017 - APPLIANCE DEFECT

Your form has a new entry.

Here are the results.

DateDec 29, 2017
First and Last NameEric Smo
Entry TypeAPPLIANCE DEFECT
Your entry
Dry Chem Found Empty on AT715, placed in dayroom Thea Ticket Written...needs to go to small tools
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Dec 29, 2017 - APPLIANCE DEFECT

Your form has a new entry.

Here are the results.

DateDec 29, 2017
First and Last NameEric Smo
Entry TypeAPPLIANCE DEFECT
Your entry
Dry Chem Found Empty on AT715
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Dec 29, 2017 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateDec 29, 2017
First and Last NameEric Smo
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITOTHER
OTHER UNIT
SPECIFY UNIT ID RS715 (RS742)
Your entry
Driver's Side and Center Quartz Lights (Brow Lights) OOS
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Dec 29, 2017 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateDec 29, 2017
First and Last NameL. Newman
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITA715
Your entry
This is to inform you that Leonard Newman reporting from station 15 has submitted the following defect report for Stock #3-16-7034.

Defect Description: Intermittent air leak in rear air suspension system. When occurring, air can be heard escaping from the rear suspension area, the rear air tank remains at zero PSI, and the main chassis air tank will pressurize only to ~90PSI on high idle and drop quickly once high idle is released. Air loss continues until the parking brake applies itself. During 12/29 overnight shift this issue occurred after unloading patient at Holy Cross. After several unsuccessful attempts to get the system to pressurize, the unit was allowed to fast idle for 6-8 minutes or longer and the rear air tank suddenly charged to ~70-75PSI and then dropped to ~40PSI, and then the main air tank charged normally. While driving unit in OOS status back to quarters, rear air tank pressure fluctuated randomly and quickly between 25-60 PSI. Declared unit OOS due to parking brake self-applying and rear air suspension dropping when air leak condition occurs.

Is Out Of Service? Yes
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Thursday, December 28, 2017

A715 OOS

FYI


A715 made it back to quarters this morning but will be placed OOS due to an intermittent air leak.  EMT Len Newman will be completing a defect report once he switches into RA13.  They are headed to Station 21 to pick it up now.  As of 0230 A715 is still OOS and will be placed in service once they switch over. 


****A715 will need a tow to CMF later this morning****  12/29/17


Captain Pedro Meneses
Station Commander
Montgomery County Fire and Rescue
Burtonsville Co.15 A-Shift
13900 Old Columbia Pike
Silver Spring MD 20904
240-773-4715
Rail Liaison Officer (RAIL708)
Cell: 240-393-6756

Wednesday, December 27, 2017

Dec 27, 2017 - APPLIANCE DEFECT

Your form has a new entry.

Here are the results.

DateDec 27, 2017
First and Last NameCaptain Clemens
Entry TypeAPPLIANCE DEFECT
Your entry
Front load GE washing machine in bunkroom area
1. leaks water out the front onto the floor
2. the door is falling off its hinge something is broken
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Dec 27, 2017 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateDec 27, 2017
First and Last NameCaptain Clemens
Entry TypeGENERAL PASS ON
Your entry
Someone came by to fix the security camera issue. He said someone needed to log back into the system to run the program.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Dec 27, 2017 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateDec 27, 2017
First and Last NameCaptain Clemens
Entry TypeGENERAL PASS ON
Your entry
Medic Bay door was worked on today. electrician was here doing work on door.
Door repairman said he found some other things wrong and was going to have to come back.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Dec 27, 2017 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateDec 27, 2017
First and Last NameCaptain Clemens
Entry TypeGENERAL PASS ON
Your entry
Captain Clemens
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Dec 27, 2017 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateDec 27, 2017
First and Last NameAFC Ryman
Entry TypeGENERAL PASS ON
Your entry
Tru Fuel Update: Order is now scheduled to arrive on or after 1/3.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Tuesday, December 26, 2017

Dec 26, 2017 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateDec 26, 2017
First and Last NameAndrew Wooden
Entry TypeGENERAL PASS ON
Your entry
PE715 (Crimson) was involved in a collision, was taken to CMF. Change over into RE-9 (Pierce). All items were taken from Crimson and placed onto RE-9. All nozzles belong to PE715 (Crimson). Only hose from PE715 was the 4" LDH (1200') and short shot sections, in addition (2) 50' sections were taken from Sta 15 storage for the bumper line. A sheet has been placed on Captain's Office with details about hose compliment.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Dec 26, 2017 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateDec 26, 2017
First and Last NameDaniel Hudson
Entry TypeGENERAL PASS ON
Your entry
Metropolitan Rolling Door Company worked all day on M715 bay door. Still has mechanical issues and electrician type work that needs to be completed. Door is still out of service, and technician cannot advise if they will be back tomorrow or not.

Dec 26, 2017 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateDec 26, 2017
First and Last NameDaniel Hudson
Entry TypeGENERAL PASS ON
Your entry
The large (temporary) station generator was removed from the parking lot today.

Monday, December 25, 2017

Dec 25, 2017 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateDec 25, 2017
First and Last NameAFC Ryman
Entry TypeGENERAL PASS ON
Your entry
A pallet of Tru Fuel should be arriving this week. Please leave in the engine bay and I will take care of it from there.

Dec 25, 2017 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateDec 24, 2017
First and Last NameCaptain Clemens
Entry TypeGENERAL PASS ON
Your entry
Headsets on AT715 (RAT2) cut out when federal que is hit and sometimes it briefly cuts out.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Saturday, December 23, 2017

Dec 23, 2017 - APPLIANCE DEFECT

Your form has a new entry.

Here are the results.

DateDec 22, 2017
First and Last NameDaniel Hudson
Entry TypeAPPLIANCE DEFECT
Your entry
The kitchen sink is leaking at the garbage disposal. While running water in the sink or by running the dishwasher, water is seen leaking from back of disposal. Defect reports have been made in both reporting systems (DGS and MCFRS Facilities).
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Dec 23, 2017 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateDec 22, 2017
First and Last NameDaniel Hudson
Entry TypeGENERAL PASS ON
Your entry
The dishwasher and clothes dryer have both been replaced/installed today. Both seem to be functioning.

Friday, December 22, 2017

Dec 22, 2017 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateDec 22, 2017
First and Last NameMFP Carter
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITM715
Your entry
Patient compartment HVAC unit not working. Switched out into RA18. M715 was taken to CMF to be evaluated at a future date.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Thursday, December 21, 2017

Dec 21, 2017 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateDec 21, 2017
First and Last NameMatt Lyons
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITT715
Your entry
Tower's officer side tail / brake light is out. Officer's side rear compartment will pop open while driving down the road. Held closed by bungee cord
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Dec 21, 2017 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateDec 21, 2017
First and Last NameCaptain Clemens
Entry TypeGENERAL PASS ON
Your entry
Officer head set AT715 broken plastic piece holding on head band
Telecomm ticket written by Lyons
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Dec 21, 2017 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateDec 21, 2017
First and Last NameCaptain Clemens
Entry TypeGENERAL PASS ON
Your entry
Temporary hydrant work in 24's are off Tamarack
Copy of map for area in Captain Office. 2nd copy in front of Engine's 24 map book
Typcially the temp hydrant are in location where hydrants are.
I haven't been over to look at this yet. I got this late in the shift.

Bay door #4 (Medic Bay) Update

Should be fixed by next week.


Begin forwarded message:

From: "Long, Robert" <Robert.Long@montgomerycountymd.gov>
Date: December 21, 2017 at 9:01:42 AM EST
To: "Banks, William" <William.Banks@montgomerycountymd.gov>
Cc: Malkin Joshua B. <Joshua.Malkin@montgomerycountymd.gov>
Subject: RE: Outstanding issues

Bill,

They had to order a gear head trolley operator for the door . It is due to ship on Tuesday 12/26 and should be installed by Friday 12/29.

Thanks,

Bob

 

Robert Long

Maintenance Renovation Inspection Specialist

Department of General Services

Division of Facilities Management

1301 Seven Locks Road

Rockville, MD 20854

Office: 240-777-5370

Wednesday, December 20, 2017

Dec 20, 2017 - STATION DEFECT

Your form has a new entry.

Here are the results.

DateDec 20, 2017
First and Last NameJeffrey Weber
Entry TypeSTATION DEFECT
Your entry
Security camera monitor in watch office not functioning properly. Russell Hartung contacted - EAI Services will be at station in next couple of days to fix the problem. All security cameras are otherwise functioning correctly.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Tuesday, December 19, 2017

Dec 19, 2017 - APPLIANCE DEFECT

Your form has a new entry.

Here are the results.

DateDec 19, 2017
First and Last NameCaptain Meneses
Entry TypeAPPLIANCE DEFECT
Your entry
Washer in Laundry has no hot water running even though hose and valve are open.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Dec 19, 2017 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateDec 19, 2017
First and Last Namechris higgins
Entry TypeGENERAL PASS ON
Your entry
RS742B running as RS715 all equipment is RS742B except for:
6 SCBA
MDC
Maps
thermal Imager
Door opener
4 Portable Radios
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Dec 19, 2017 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateDec 19, 2017
First and Last Namechris higgins
Entry TypeGENERAL PASS ON
Your entry
RRS1 to station 17 all equipment was placed in back bay
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Dec 19, 2017 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateDec 19, 2017
First and Last NameChazz Smith
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITA715
Your entry
Parking brake release broke attempting to release brake. Fixed in house at time of incident. Ticket written up for defect, no repairs or inspection performed by CMF.
IF DEFECT, WAS A REPAIR REQUEST MADE?Ticket written in Fleet Management

Monday, December 18, 2017

Dec 18, 2017 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateDec 18, 2017
First and Last NameJames Hall
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITPE715 (CRIMSON)
Your entry
1 1/2" double female and 2 1/2" to 1 1/2" reducer missing during inventory. Submitted defect through THEA.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Dec 18, 2017 - APPLIANCE DEFECT

Your form has a new entry.

Here are the results.

DateDec 18, 2017
First and Last NameCaptain Clemens
Entry TypeAPPLIANCE DEFECT
Your entry
AT715 New Dry chemical extinguisher picked up at small tools
Old one dropped off
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Dec 18, 2017 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateDec 18, 2017
First and Last NameAFC Ryman
Entry TypeGENERAL PASS ON
Your entry
E715B Update: Air and fuel leaks have been handled. Spring repair is ongoing. Unit is due for PM/DOT on 1/4.

T715 Update from CMF:
Radiator is going to have to be replaced; after tightening fasteners per Pierce warranty, still leaking. New style radiator will be going back in but parts are not here. As we learned on the new towers, there are some mods that take place with the new style (cooler relocation, etc.). I do not anticipate seeing this truck back this week or next.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Sunday, December 17, 2017

Dec 17, 2017 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateDec 17, 2017
First and Last NameMatthew Miller (19A)
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITM715
Your entry
Both brake fluid reservoirs low, however no visible leaks. Entered in THEA. All tires filled to 110psi.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Dec 17, 2017 - STATION GENERATOR CHECK

Your form has a new entry.

Here are the results.

DateDec 17, 2017
First and Last NameDaniel Hudson
Entry TypeSTATION GENERATOR CHECK
STATION GENERATOR CHECK
Fuel level99%
Coolant temp120
Run hrs224.36
Oil Ok?Yes
Visual inspection ok?Yes
Defect report written?No

Dec 17, 2017 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateDec 17, 2017
First and Last NameDaniel Hudson
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITT715
Your entry
T715 dry chemical extinguisher needs to be replaced. MFF Wright will deliver to Small Tools on 12/18. No spares in station to place on T715.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Dec 17, 2017 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateDec 17, 2017
First and Last NameDaniel Hudson
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITT715
Your entry
T715 dry chemical extinguisher needs to be replaced. MFF Wright will deliver to Small Tools on 12/18.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Friday, December 15, 2017

Dec 15, 2017 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateDec 15, 2017
First and Last NameLt. Branch
Entry TypeGENERAL PASS ON
Your entry
The dryer in the hallway was repaired today. It is currently being used to test function. A serviceman repaired it approximately 2030hrs. He left without leaving paper work documenting service.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Dec 15, 2017 - APPLIANCE DEFECT

Your form has a new entry.

Here are the results.

DateDec 15, 2017
First and Last NameMatt Lyons
Entry TypeAPPLIANCE DEFECT
Your entry
Dishwasher is broken AGAIN. It leaked water all over the floor halfway thru a wash cycle.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Dec 15, 2017 - APPLIANCE DEFECT

Your form has a new entry.

Here are the results.

DateDec 15, 2017
First and Last NameCaptain Clemens
Entry TypeAPPLIANCE DEFECT
Your entry
K12 saw had pull chord pulled out
It was repaired by small tools
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Dec 15, 2017 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateDec 15, 2017
First and Last NameCaptain Clemens
Entry TypeGENERAL PASS ON
Your entry
RS715 Imager repaired
New screws placed in with blue lock-tite
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Thursday, December 14, 2017

Dec 14, 2017 - STATION DEFECT

Your form has a new entry.

Here are the results.

DateDec 14, 2017
First and Last NameScott Cook
Entry TypeSTATION DEFECT
Your entry
Chuck from DGS came by today. He replaced a duct sensor in the volunteer meeting room.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Monday, December 11, 2017

Dec 11, 2017 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateDec 11, 2017
First and Last NameAFC Ryman
Entry TypeGENERAL PASS ON
Your entry
It is likely noticable that a good portion of RS715's equipment is no longer in the engine bay. We are working to get as much as possible (that doesn't have fuel, mineral oil, or hydralic fluid in it) organized into the 1st single dorm room on the right when you walk into the addition.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Sunday, December 10, 2017

Dec 10, 2017 - STATION GENERATOR CHECK

Your form has a new entry.

Here are the results.

DateDec 10, 2017
First and Last Namechris higgins
Entry TypeSTATION GENERATOR CHECK
STATION GENERATOR CHECK
Fuel level99%
Coolant temp120
Run hrs224
Oil Ok?Yes
Visual inspection ok?Yes
Defect report written?No

Dec 10, 2017 - APPLIANCE DEFECT

Your form has a new entry.

Here are the results.

DateDec 10, 2017
First and Last NameCaptain Clemens
Entry TypeAPPLIANCE DEFECT
Your entry
Guess what appliances isn't cleaning dishes again....
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Saturday, December 9, 2017

Dec 09, 2017 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateDec 09, 2017
First and Last NameMatt Lyons
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITA715
Your entry
Operation of the air compressor is very delayed, even at high idle and higher RPMs while driving. The delay causes a lack of pressure build up in the air ride system, causing the patient box to ride extremely rough. Operation of the parking brake is not effected.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Friday, December 8, 2017

Dec 08, 2017 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateDec 08, 2017
First and Last NameScott Cook
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITPE715B (PIERCE)
Your entry
E715B taken to CMF this morning.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Thursday, December 7, 2017

Dec 07, 2017 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateDec 07, 2017
First and Last NameWillie Owens
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITPE715B (PIERCE)
Your entry
E715B is OOS for the following defects...
Does not pass brake test due to air leak at transfer valve.
Broken leaf spring in middle of stack on officer side rear.
Leaking fuel from fuel line that runs along officer side frame rail above muffler.
Voltage gauge OOS

Ticket written and BC notified so apparatus tracker could be updated.
Please communicate with CMF in the morning so we can figure out if they want it or want it taken elsewhere.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Wednesday, December 6, 2017

Dec 06, 2017 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateDec 06, 2017
First and Last NameCaptain Clemens
Entry TypeGENERAL PASS ON
Your entry
Back in RRS1
RS742B returned to BCC
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Tuesday, December 5, 2017

Dec 05, 2017 - STATION DEFECT

Your form has a new entry.

Here are the results.

DateDec 05, 2017
First and Last NameDaniel Hudson
Entry TypeSTATION DEFECT
Your entry
HVAC re-wiring work has been completed, EXCEPT the thermostat in the kitchen/dining area. That thermostat has been set to fan-only, and tagged to leave it in that setting. Technician is unable to provide a date when they will return to correct that one, it's in the hands of the project manager.

Dec 05, 2017 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateDec 05, 2017
First and Last NameDaniel Hudson
Entry TypeGENERAL PASS ON
Your entry
M2 portable radio back in service. Loaner returned to BC701.

Monday, December 4, 2017

Dec 04, 2017 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateDec 04, 2017
First and Last NameBrett Carter
Entry TypeGENERAL PASS ON
Your entry
The Crimson was picked up from CMF and placed back in service. Change over list is on the line up board. There is currently 1650 feet of 4" supply line on the Crimson. 850' on the Humat and 800' on the Siamese. The Bravo wagon is reserve ready and currently parked in the Medic Bay.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Dec 04, 2017 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateDec 04, 2017
First and Last Namechris higgins
Entry TypeGENERAL PASS ON
Your entry
RS741B running as RS715 4 portable radios, maps, and door opener, and MDC was placed on RS741B. RS741B MDC placed in capt. office
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Dec 04, 2017 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateDec 04, 2017
First and Last Namechris higgins
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITOTHER
OTHER UNIT
SPECIFY UNIT ID RRS1
Your entry
RRS1 was taken to CMF today for the back door latch, while at CMF a mechanic was injured when equipment fell out of a compartment. CMF deemed the SQ unsafe and could not leave CMF and all equipment must stay on the RS until investigated.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Dec 04, 2017 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateDec 04, 2017
First and Last Namechris higgins
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITT715
Your entry
T715 was placed OOS for a coolant leak, O ring on top of the radiator is bad. RAT 2 is running as T715, all equipment was switched over except ladders and pry bar.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Sunday, December 3, 2017

Dec 03, 2017 - STATION GENERATOR CHECK

Your form has a new entry.

Here are the results.

DateDec 03, 2017
First and Last NameCaptain Clemens
Entry TypeSTATION GENERATOR CHECK
STATION GENERATOR CHECK
Fuel level99%
Coolant temp115
Run hrsn/a
Oil Ok?Yes
Visual inspection ok?Yes
Defect report written?No

Dec 03, 2017 - SCBA DEFECT REPORT

Your form has a new entry.

Here are the results.

DateDec 02, 2017
First and Last NameAFC Ryman
Entry TypeSCBA DEFECT REPORT
SCBA
Date sent outDec 03, 2017
SCBA designation ie (E715 Left, Spare 1)T715 R
Reason for unscheduled maintenanceRegulator in pieces, slammed in door
Spare used?Spare 3

Dec 03, 2017 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateDec 02, 2017
First and Last NameAFC Ryman
Entry TypeGENERAL PASS ON
Your entry
A hook was installed on the wall of the T3 position as another SCBA regulator was damaged yesterday following being slammed in the door.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Saturday, December 2, 2017

Dec 02, 2017 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateDec 02, 2017
First and Last NameScott Cook
Entry TypeGENERAL PASS ON
Your entry
There is a hydrant near 14100 Castle Blvd. This hydrant is all white in color and has not had the proper bonnet top since I have been here. I have contacted WSSC a few times to no avail. Following FCGO 17-13, Fire Safety Code procedures, I filed a complaint with code.

We'll see what happens...
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Dec 02, 2017 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateDec 02, 2017
First and Last NameM. Bulla
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITOTHER
OTHER UNIT
SPECIFY UNIT ID RRS1
Your entry
Bottom latch for right-most changeable number in the rear of the squad is broken.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Dec 02, 2017 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateDec 02, 2017
First and Last NameM. Bulla
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITOTHER
OTHER UNIT
SPECIFY UNIT ID RRS1
Your entry
Bottom part of latch for walk-in door not in the correct position, making it difficult to correctly latch the door. The piece is inside the door and may be bent - it's not fixable without taking off the inside door panel.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Dec 02, 2017 - STATION DEFECT

Your form has a new entry.

Here are the results.

DateDec 02, 2017
First and Last NameM. Charlton
Entry TypeSTATION DEFECT
Your entry
Station alerting system visual indicator in the day room did not illuminate for RS715 alert for incident #17-006007877
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Friday, December 1, 2017

Dec 01, 2017 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateDec 01, 2017
First and Last NameAFC Ryman
Entry TypeGENERAL PASS ON
Your entry
Two representatives from CRW were at the station all day today and they think they found the issue with HVAC. There are 13 air handlers all together. They checked the wiring on 5, of which four out of the five were all wired (routed) incorrectly . Tyler the Project Manager is aware of everything and Siemens will be here on Monday to redo the wiring and check the remaining handlers to ensure they are also wired correctly.

He said that this only became an issue with the recent weather since every area is trying to heat and cool at different times exposing the improperly routed wiring. (For example, my thermostat might have controlled the kitchen). It was not an issue in the summer because all areas simply needed to be cooled.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO