Wednesday, November 30, 2022

Nov 30, 2022 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 30, 2022
First and Last NameSmo
Entry TypeGENERAL PASS ON
Your entry
Update: Front apron back in-service
Heat update for the station: County Vendor in Quarters. Closed Cold air intake, cleaned a bunch of filters in the ceiling in an attempt to see if that remedied the situation. Plans to come back (tomorrow) Wednesday with a contractor. Brian Vane in quarters and dropped off 4 space heaters in the meantime. To be continued.

Nov 30, 2022 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateNov 30, 2022
First and Last NameHarris
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITT715
Your entry
Rat6 had bad seal on auto level for bucket; dumped fluid; written up; CMF told they could fix, 8 hours later they burst hydraulic line in ladder tubing; switched out to RT5; everything (including little giant) switched except cribbing and ladders in rear; RT5 generator broken and also rear ladder latching door handle
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Tuesday, November 29, 2022

Nov 29, 2022 - STATION DEFECT

Your form has a new entry.

Here are the results.

DateNov 29, 2022
First and Last NameMichael Moore
Entry TypeSTATION DEFECT
Your entry
The heat is still not operating appropriately. Another defect was entered about the issue. If the HVAC tech is seen in quarters please speak to him. He has been seen in the building the last two days but leaves before speaking to anyone.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Nov 29, 2022 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 29, 2022
First and Last NameHiggins
Entry TypeGENERAL PASS ON
Your entry
A715 pulse ox cable was broken, cable from RS715 pulse ox was placed on A715. Cody is going to pick one up a replacement from EMS logistics
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Nov 29, 2022 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 29, 2022
First and Last NameHiggins
Entry TypeGENERAL PASS ON
Your entry
Station Fuel key is MIA waiting to hear back from C shift to see if they know where it might be.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Nov 29, 2022 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateNov 29, 2022
First and Last NameJason Eberly
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITPE715 (PIERCE)
Your entry
Red 50' Section of 4" hose damaged on PE715. Replacement was placed in service and defect was written requesting a replacement for damaged section. Damaged section is by back door.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Nov 29, 2022 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateNov 29, 2022
First and Last NameMcDonald
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITRS715 (E-ONE)
OTHER UNIT
SPECIFY UNIT ID RS715
Your entry
Both front tires on the heavy are at 4/32" tread depth. Defect written.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Monday, November 28, 2022

Nov 28, 2022 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 28, 2022
First and Last NameCaptain Clemens
Entry TypeGENERAL PASS ON
Your entry
Found Sonim phone for M715 under the Officer seat. DC charger was found broken.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Sunday, November 27, 2022

Nov 27, 2022 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 27, 2022
First and Last NameSmo
Entry TypeGENERAL PASS ON
Your entry
SONIM Phone missing from medic unit. Check with your shifts to see where it could be.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Saturday, November 26, 2022

Nov 26, 2022 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 26, 2022
First and Last NameWillie O
Entry TypeGENERAL PASS ON
Your entry
The Milwaukee battery power saw is in and has been placed on the Engine.
**Please remember, if there is an issue with it, it is to be written up in small tools as the saw that belongs to the Truck so that Small tools will cover it.

Nov 26, 2022 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 26, 2022
First and Last NameChief Ryman
Entry TypeGENERAL PASS ON
Your entry
RAT 6 is back running as T715. All equipment except ladders switched over.
T715 written up for overheating. Fan clutch was not engaging. Radios also started turning totally off when utilizing the federal. Hi idle is also still not working but CMF had deleted the defect so that was resubmitted.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Nov 26, 2022 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateNov 26, 2022
First and Last NameChief Ryman
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITT715
Your entry
T715 radios are intermittently cycling through start up process but never totally turning off. TSR was submitted. Per Tech Ops this is a power issue and CMF needs to look at it this week.
T715 aerial appears to be past due to be cleaned and greased.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Wednesday, November 23, 2022

Nov 23, 2022 - STATION DEFECT

Your form has a new entry.

Here are the results.

DateNov 24, 2022
First and Last NameChief Ryman
Entry TypeSTATION DEFECT
Your entry
All exterior lighting is out on the B side of the building. Lights on the building itself and over the walkway.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Nov 23, 2022 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 23, 2022
First and Last NameMcDonald
Entry TypeGENERAL PASS ON
Your entry
IT contractors in station to look at engine bay monitor screens. Issue narrowed down to the splitters (mainly the one above white board in kitchen) and differences in resolution settings between each monitor. Contractors stated that monitors on each splitter should have same resolution setting. If issue occurs again try "resetting" TV monitors to default resolution settings.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Nov 23, 2022 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 23, 2022
First and Last NameMcDonald
Entry TypeGENERAL PASS ON
Your entry
HVAC tech in station advised that an outside air damper was left in open position causing significant amount of cold air to enter station. Damper closed and heat seems to be working fine now.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Tuesday, November 22, 2022

Nov 22, 2022 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 22, 2022
First and Last NameMarvin Robinson
Entry TypeGENERAL PASS ON
Your entry
CMF Dropped off enough absorbent to fill apparatus buckets and trash can in compressor room.

Nov 22, 2022 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 22, 2022
First and Last NameCaptain Clemens
Entry TypeGENERAL PASS ON
Your entry
HVAC man came back out today for the heat in the firehouse. He did some work and left. We don't know if he is done or coming back.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Nov 22, 2022 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 22, 2022
First and Last NameCaptain Clemens
Entry TypeGENERAL PASS ON
Your entry
TSR written for 3 screens in the Engine room this morning. Two attempts to reboot remotely were unsuccessful. Ticket # 22-4511
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Monday, November 21, 2022

Nov 21, 2022 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 21, 2022
First and Last NameRobert Marsh
Entry TypeGENERAL PASS ON
Your entry
Sink on far right in Men's Room clogged. Written up in Station defect reporting system.
Heat will not get above 66. Called it out as an urgent issue. Facilities is supposed to come out today and take a look. Also wrote it up in station defect system.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Thursday, November 17, 2022

Nov 17, 2022 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 17, 2022
First and Last NameJason Eberly
Entry TypeGENERAL PASS ON
Your entry
Order placed for 10 bags of absorbent.

Nov 17, 2022 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 17, 2022
First and Last NameJason Eberly
Entry TypeGENERAL PASS ON
Your entry
TU-28 Griphoist sheer pins replaced and unit placed back in service on RS715. Extra sheer pins for TU-28 were placed in a labeled zip loc bag placed in the tool box.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Wednesday, November 16, 2022

Nov 16, 2022 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 16, 2022
First and Last NameCaptain Clemens
Entry TypeGENERAL PASS ON
Your entry
4 griphoist sheer pins picked up from small tools
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Nov 16, 2022 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 16, 2022
First and Last NameCaptain Clemens
Entry TypeGENERAL PASS ON
Your entry
Truck 715 back in service. Does anyone know the location of the T715 Left portable radio lapel Mic ?
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Tuesday, November 15, 2022

Nov 15, 2022 - STATION DEFECT

Your form has a new entry.

Here are the results.

DateNov 15, 2022
First and Last NameRob Rogers
Entry TypeSTATION DEFECT
Your entry
SCBA Refill Station has an air leak from an undetermined source from inside of the system. When locking the revolving door to begin filling cylinders, air begins to leak loudly and stops when the lock is released.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Monday, November 14, 2022

Nov 14, 2022 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 14, 2022
First and Last NameChief Ryman
Entry TypeGENERAL PASS ON
Your entry
Small tools has confirmed they have shear pins for the small griphoist (they think) in stock. If a unit can take it to small tools they will replace the pins and provide spares.
Please try to get spares for the big one too.
The griophoist is on the floor next to the FE prop so its not used on a call.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Sunday, November 13, 2022

Nov 13, 2022 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 13, 2022
First and Last NameChief Ryman
Entry TypeGENERAL PASS ON
Your entry
The squad was given a solid once over after MATR class this weekend and as much as possible powerwashed from the unit and equipment. The inside was also cleaned. It will need another once over in a day or two to remove any additional sand.
1 snatchblock is missing a cotter pin
2 hitch pins are missing for anchor points, both of these issues were written up.
Large enerpac pump likely has an air buddle in the system and the guage. Will work on this later this week. The pump functions fine.
Saturday morning all of the slings on the driver's side heavy rigging compartment were found soaked and one come a long box was half full of water. We could not locate the source of the leak. I will discuss with Patriot tomorrow.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Saturday, November 12, 2022

Nov 12, 2022 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 12, 2022
First and Last NameChief Ryman
Entry TypeGENERAL PASS ON
Your entry
Trailblazer dropped off at sport for service.
Sheer pin broken on RS715 smaller griphoist.
1 piece blue 15' wedding from RS715 oos.
Defects being submitted. Extra sheer pins will be requested.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Thursday, November 10, 2022

Nov 10, 2022 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 10, 2022
First and Last NameChief Ryman
Entry TypeGENERAL PASS ON
Your entry
Due to the apron replacement project, USPS will not be delivering mail to the firehouse for the next week or two. Mail is being diverted to the Colesville office and will be picked up a few times per week until the front apron can be driven on again.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Tuesday, November 8, 2022

Nov 08, 2022 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateNov 09, 2022
First and Last NameChief Ryman
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITRS715 (E-ONE)
Your entry
TSR submitted for RS headsets not functioning normally.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Nov 08, 2022 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 08, 2022
First and Last NameMcDonald
Entry TypeGENERAL PASS ON
Your entry
Patriot was in to service RS715 light tower and air system. Light tower repaired, but air leak at regulator remains. Patriot/SCBA shop looking into issue.
Work on front ramp began today. Apparatus repositioned and running out of rear of firehouse.
SCBA Shop techs were out and repaired station compressor / SCBA fill station.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Nov 08, 2022 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateNov 08, 2022
First and Last NameKelly Barnard
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITOTHER
OTHER UNIT
SPECIFY UNIT ID RA-1
Your entry
Built-in charging cable for ePCR not charging computer. Charging cord plugged into ledge outlet.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Monday, November 7, 2022

Nov 07, 2022 - APPLIANCE DEFECT

Your form has a new entry.

Here are the results.

DateNov 07, 2022
First and Last NameCaptain Clemens
Entry TypeAPPLIANCE DEFECT
Your entry
T715 Cutters Edge chain guard nut was replaced
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Nov 07, 2022 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateNov 07, 2022
First and Last NameStarin
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITA715
Your entry
A715 was switched out due to the power load system issue, now running RA-1
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Sunday, November 6, 2022

Nov 06, 2022 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateNov 06, 2022
First and Last NameWillie O
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITA715
Your entry
A715 striker power cot is not unloading correctly and causing the cot to lock up half way out of the unit. When you hit the red release button, the cot is supposed to automatically raise to its normal unloading position. It isn't doing this so you will need to hold the track in place with your hand while activating the cot release button and gently pull the cot out a few inches. This will allow the cot to automatically raise and function as normal.
Please make sure this is passed on to the next crew at shift change to ensure they are aware of the issue and to everyone else to make sure they are aware of how to unload the cot until we can have it repaired. The Ambulance will need to go to CMF on Monday morning to have the power cot system repaired.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Nov 06, 2022 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 06, 2022
First and Last NameLauren Chrosniak
Entry TypeGENERAL PASS ON
Your entry
Cot gets stuck when pulling it out of the ambulance even though there is nothing in the way of the tracks. Need to slide the red release switch under the cot after it gets stuck to release it.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Nov 06, 2022 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 06, 2022
First and Last NameLauren Chrosniak
Entry TypeGENERAL PASS ON
Your entry
Portable pulse oximeter not reading. The cord leading to the monitor is kinked and a new probe is needed for it to function. It functions properly when using the probe from the vitals monitor.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Saturday, November 5, 2022

Nov 05, 2022 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateNov 05, 2022
First and Last NameSantos Diaz
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITT715
Your entry
Cutter edge chain saw found missing chain guard nut. Small tools repair request made. Saw still on apparatus.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Friday, November 4, 2022

Nov 04, 2022 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 04, 2022
First and Last NameE. Winston
Entry TypeGENERAL PASS ON
Your entry
The onboard air system on the tower was charged to 95% this morning. Throughout the day we noticed system stilled leaked. Air whips were taken off the unit and placed back in the Capt's office.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Wednesday, November 2, 2022

Nov 02, 2022 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 02, 2022
First and Last NameChris Miller
Entry TypeGENERAL PASS ON
Your entry
RS715 RIT Bag Battery Console Repaired
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Nov 02, 2022 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 02, 2022
First and Last NameChris Miller
Entry TypeGENERAL PASS ON
Your entry

RE-15 Equipment (Left on Eng Co)
24' Extension Ladder
14' Roof Ladder
Hard Sleeve x 2
Low Level Strainer
4" LDH Supply Beds
2 1/2"
3"
The remaining hose taken off RE-15 was left with the Pierce Eng.
All of the other remaining equipment on RE-15. belongs to Co. 15
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Tuesday, November 1, 2022

Nov 01, 2022 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 01, 2022
First and Last NameCaptain Clemens
Entry TypeGENERAL PASS ON
Your entry
New Metrorail maps coming for RS715 and E715
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Nov 01, 2022 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 01, 2022
First and Last NameRogers
Entry TypeGENERAL PASS ON
Your entry
Brush Truck Portable Radio replaced with newly programmed radio by radio shop.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO