Friday, June 30, 2023

Jun 30, 2023 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateJun 30, 2023
First and Last NameKitner
Entry TypeGENERAL PASS ON
Your entry
-RAT 2 placed OOS, the aerial ladder decided to retract itself multiple times a few inches at a clip. RAT 4 which is an allsteer is all that was there. The MDC mount is one of the old mounts so the MDC is kinda rigged up in there. We will address it Monday when the radio shop is open.
-Counter top installed in laundry room
- E715 Ventis meter back in service
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Thursday, June 29, 2023

Jun 29, 2023 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateJun 29, 2023
First and Last NameMichael Gignac
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITA715
Your entry
Driver's rear inside tire was flat at start of shift. Defect report was made and tire was inspected by Rice Tire. Valve stem core was replaced as a precaution. No road hazard damage was found during inspection.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Wednesday, June 28, 2023

Jun 28, 2023 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateJun 28, 2023
First and Last NameRob Rogers
Entry TypeGENERAL PASS ON
Your entry
1. RAT2 - a few defects written up... 1-2 min delay on emergency lights activating after start-up, gradually taking longer to start the vehicle even after being plugged in, sluggish aerial movement and no way to verify or fill aerial hydraulic fluid... even the CMF aerial mechanic couldn't find the fill port/dipstick. Good news is the cab tilt works and we got a new manual handle for it, if the electric cab tilt breaks.
2. OOS LDH section swapped at A9, new section placed on rack with other spare hose
3. RS15 Cutters Edge brought back from A9 and placed in service
4. Spare break away shoreline plug replaced by A9, placed in the Shop
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Jun 28, 2023 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateJun 28, 2023
First and Last NameJames Schultz
Entry TypeGENERAL PASS ON
Your entry
SONIM Phones for Rescue, Truck, and Ambulance placed back in service with new batteries that were delivered.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Tuesday, June 27, 2023

Jun 27, 2023 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateJun 27, 2023
First and Last NameKitner
Entry TypeGENERAL PASS ON
Your entry
Sonim phones for Truck, Rescue Squad and Ambo OOS in Captains office, they all need new batteries.
RS15 Officers pack sent out for repair, spare in its place
Knox box key for RS15 missing again
Switched Towers from one piece of junk into another piece of junk Now running RAT2
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Monday, June 26, 2023

Jun 26, 2023 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateJun 26, 2023
First and Last NameCaptain Clemens
Entry TypeGENERAL PASS ON
Your entry
New Treadmill !
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Jun 26, 2023 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateJun 26, 2023
First and Last NameRob Rogers
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITOTHER
OTHER UNIT
SPECIFY UNIT ID AT715 (RAT3)
Your entry
Neither manual or electric cab tilt functions work on the Tower and the manual cab tilt handle is MIA. Called CMF this morning to discuss, will be taking the vehicle up to CMF in the morning on 6/27 for assessment.
Also wrote up the tower for having a rough start / misfire and lots of white exhaust. Only happened once today.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Sunday, June 25, 2023

Jun 25, 2023 - STATION DEFECT

Your form has a new entry.

Here are the results.

DateJun 25, 2023
First and Last NameChief Ryman
Entry TypeSTATION DEFECT
Your entry
Facilities came out and reset both issue AC units. As usual they are not able to work on this system and will have to have CBS come out, likely tomorrow. They did state it is odd our sytem's fans do not run all the time.
While on the roof the following was noted:
- there is membrance deterioration near each AC units in the rear (defect submitted)
-Every roof drain was clogged up and had a large pool of standing water around it. I cleared each drain and got the water to drain, but these need to be periodically dealt with to avoid the roof leaks we constantly get near the compressor room and the watchdesk.
A defect was submitted for condensation dripping from vents in the kitchen.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Saturday, June 24, 2023

Jun 24, 2023 - STATION DEFECT

Your form has a new entry.

Here are the results.

DateJun 24, 2023
First and Last NameChief Ryman
Entry TypeSTATION DEFECT
Your entry
AC is not working well in the rear of the building. Facilities was called and remoted into the system to attempt to adjust. A tech will be out in the morning regardless.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Jun 24, 2023 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateJun 23, 2023
First and Last NameCaptain Clemens
Entry TypeGENERAL PASS ON
Your entry
E715B is at station 12
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Friday, June 23, 2023

Jun 23, 2023 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateJun 23, 2023
First and Last NameRob Rogers
Entry TypeGENERAL PASS ON
Your entry
1. T15 placed OOS: Oil Pressure reading 85psi and Coolant Temp spikes to max reading. Unable to confirm proper readings, or if correct... very bad things are happening in the engine. CMF stated that the oil sample they sent out came back with traces of coolant. So it'll probably be out for a while. Switched into RAT3. The only equipment left on T15 was the 14' fiberglass pike pole from the rear compartment.
2. RS chainsaw taken to A9 for repairs, still being repaired as we departed CMF
3. Swapped out Dry Chem Extinguisher at A9.
4. SCBA Shop was closed so loaner RIT pack still needs to go back via the courier or by one of our A9/Logistics part timers.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Thursday, June 22, 2023

Jun 22, 2023 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateJun 22, 2023
First and Last NameJames Schultz
Entry TypeGENERAL PASS ON
Your entry
-RS715 RIC PACK returned and placed back on the squad.
-Loaner TIC placed in the RS3 position on RS715.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Tuesday, June 20, 2023

Jun 20, 2023 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateJun 20, 2023
First and Last NameMarvin Robinson
Entry TypeGENERAL PASS ON
Your entry
Contractor came by today and filled in holes in the bay floors
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Jun 20, 2023 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateJun 19, 2023
First and Last NameRobert Marsh
Entry TypeGENERAL PASS ON
Your entry
Drain for Ice Maker seemed to be clogged last night. Written up and called facilities. They came out and appeared to fix.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Saturday, June 17, 2023

Jun 17, 2023 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateJun 17, 2023
First and Last NameN DeVries
Entry TypeGENERAL PASS ON
Your entry
dry chem used, swapped out with spare in back. defect written
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Wednesday, June 14, 2023

Jun 14, 2023 - STATION DEFECT

Your form has a new entry.

Here are the results.

DateJun 15, 2023
First and Last NameCaptain Clemens
Entry TypeSTATION DEFECT
Your entry
Bay Door #4 damage to lower panel.
Door came down on AT724
Bay door does go up and down and the station can be secured.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Jun 14, 2023 - APPLIANCE DEFECT

Your form has a new entry.

Here are the results.

DateJun 14, 2023
First and Last NamePlacek
Entry TypeAPPLIANCE DEFECT
Your entry
E715 ventis four gas meter failed bump testing multiple times on the docking station. The bravo engine's meter was placed on E715.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Jun 14, 2023 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateJun 14, 2023
First and Last NameChris Miller
Entry TypeGENERAL PASS ON
Your entry
RS715 - Cutter's Edge - Throttle is sticking and causing the engine to be flooded.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Saturday, June 10, 2023

Jun 10, 2023 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateJun 10, 2023
First and Last NameChief Ryman
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITRS715 (E-ONE)
Your entry
A TSR was submitted for the serious dock vibration issues with the new MDC dock in RS715.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Jun 10, 2023 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateJun 09, 1923
First and Last NameWillie O
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITT715
Your entry
Truck 715 was taken to CMF to have it evaluated for the possible 4 gallons of coolant consumption in one week being an internal issue. No apparent leak could be found, the truck has a rough idle, and the oil was found high on the dipstick. CMF performed a pressure test, diagnostic test, drained some oil out of the oil pan, and sent the oil out to have it inspected for any coolant. Please keep an eye on the oil level and make note of any additional coolant that is added.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Friday, June 9, 2023

Jun 09, 2023 - APPLIANCE DEFECT

Your form has a new entry.

Here are the results.

DateJun 09, 2023
First and Last NameStarin
Entry TypeAPPLIANCE DEFECT
Your entry
100' section of 4" supply line from PE715 was found delaminated, removed from service. Replaced with a section from the rack, small tools defect submitted.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Thursday, June 8, 2023

Jun 08, 2023 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateJun 09, 2023
First and Last NameJames Placek
Entry TypeGENERAL PASS ON
Your entry
Four Gas meter for came back for E715.

Jun 08, 2023 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateJun 09, 2023
First and Last NameJames Placek
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITT715
Your entry
Coolant alarm went off during the day. 1/2 Gallon added. Alarm went off again during the evening. Engine had to be shut off and and turned on to clear the alarm.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Jun 08, 2023 - STATION DEFECT

Your form has a new entry.

Here are the results.

DateJun 08, 2023
First and Last NameDane Donnelly
Entry TypeSTATION DEFECT
Your entry
PE715 Plymovent boot was damaged responding to a call. Defect submitted.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Jun 08, 2023 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateJun 08, 2023
First and Last Namekeefer
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITPE715B (PIERCE)
Your entry
bravo wagon picked up by cmf
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Jun 08, 2023 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateJun 08, 2023
First and Last Namekeefer
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITRS715 (E-ONE)
OTHER UNIT
SPECIFY UNIT ID rs715
Your entry
new mdc placed in rs
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Wednesday, June 7, 2023

Jun 07, 2023 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateJun 07, 2023
First and Last NameScott Cook
Entry TypeGENERAL PASS ON
Your entry
Plumbers and a contractor were in to replace vanities/sinks in both locker rooms. The contractor will be back to replace the laundry room counter.
Another contractor was by to look at the oven for approximately 4 hours before deciding that he did not have the parts. Oven still OOS.
A DGS employee came by to snake both urinals and they now work properly.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Jun 07, 2023 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateJun 07, 2023
First and Last NameScott Cook
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITPE715B (PIERCE)
Your entry
A light duty person will be by tomorrow to pick up the bravo engine for maintenance.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Jun 07, 2023 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateJun 07, 2023
First and Last NameSmo
Entry TypeGENERAL PASS ON
Your entry
Small Tools delivered brand new wedges. Wedges have been marked with a "15" and placed in the rear of the Squad. We have some extras in reserve as well.

Tuesday, June 6, 2023

Jun 06, 2023 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateJun 05, 2023
First and Last NameKitner
Entry TypeGENERAL PASS ON
Your entry
RA6 is running as Medic 715, real medic unit taken to CMF for DEF light issue.
Kitchen oven will not light the pilot light, defect written.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Monday, June 5, 2023

Jun 05, 2023 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateJun 05, 2023
First and Last NameMarvin Robinson
Entry TypeGENERAL PASS ON
Your entry
New RIC Pack delivered to the station and placed on T715. Loaner RIC Pack on T715 placed on RS715 and old pack on on squad sent out for replacement.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Thursday, June 1, 2023

Newly Cleared Driver

All-

Please congratulate our newest cleared EMS unit driver, EMT Mei Zheng. 



Thanks,

Michael Ryman
Fire Chief
Burtonsville VFD
13900 Old Columbia Pike
Silver Spring, Md 20904
Cell: 570-766-9054




For more helpful Cybersecurity Resources, visit: https://www.montgomerycountymd.gov/cybersecurity