Monday, November 30, 2020

Nov 30, 2020 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateNov 30, 2020
First and Last NameBenjamin Brighton
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITM715
Your entry
Apparatus almost doesn't start when not plugged in to shore line. Defect entry written.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Saturday, November 28, 2020

Nov 28, 2020 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 28, 2020
First and Last NameChief Ryman
Entry TypeGENERAL PASS ON
Your entry
The front convex mirror on the rescue squad was adjusted to provide the driver better opportunity to see it.
Harnesses were relocated to the top shelf on the right side of the walk through following some requests and discussion. Please do not continue to leave one or multiple boxes loose on the floor.
Please be careful when opening the Paratech compartment. The interior handle attached to the cable is cracking more and more. I will follow up with Patriot on Monday on the timeline for the replacement, ideally expediting it.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

RS715 cribbing tray

All-

The tray was repacked today. The way it was packed would be problematic for access to the cribbing in the back. I'm including pictures to show how the tray was designed to be packed which allows easier access. 






Michael Ryman
Fire Chief
Burtonsville VFD 
570-766-9054 




For COVID-19 Information and resources, visit: www.montgomerycountymd.gov/COVID19

Nov 28, 2020 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 28, 2020
First and Last NameChester Cadogan
Entry TypeGENERAL PASS ON
Your entry
Traction Splint left on Pt transported to White Oak Medical last night. Head Nurse (Gena) said that they will package it and leave in the EMS Room for pick when they take it off. Please look out for it and collect it to be returned to the ambulance inventory.
There is currently a spare on the Ambulance
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Friday, November 27, 2020

Nov 27, 2020 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateNov 28, 2020
First and Last NameMcDonald
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITRS715 (E-ONE)
OTHER UNIT
SPECIFY UNIT ID RS715
Your entry
Disregard Mars light issue. VMUX switch to Mars lights was apparently off when issue was noticed.
IF DEFECT, WAS A REPAIR REQUEST MADE?Defect needs to be removed

Nov 27, 2020 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateNov 27, 2020
First and Last NameMcDonald
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITRS715 (E-ONE)
OTHER UNIT
SPECIFY UNIT ID RS715
Your entry
O/S Mars 888 light out.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Nov 27, 2020 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 27, 2020
First and Last NameMister
Entry TypeGENERAL PASS ON
Your entry
EMS supplies delivered and put away. More KN95's put in the Captains office
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Nov 27, 2020 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 27, 2020
First and Last NameMister
Entry TypeGENERAL PASS ON
Your entry
Anyone know where the label maker is?
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Thursday, November 26, 2020

Nov 26, 2020 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 26, 2020
First and Last NameChief Ryman
Entry TypeGENERAL PASS ON
Your entry
Replacement pig tail for A715 came in, so E715B's was returned.
Spare Milwaukee metal saw blade added to RS715 tool box.
T715 EZ pass removed. The unit how has a tag mounted EZ pass (the black plastic box now on the top of the license plate).
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Wednesday, November 25, 2020

Nov 25, 2020 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 25, 2020
First and Last NameChief Ryman
Entry TypeGENERAL PASS ON
Your entry
There are now 2 less 7 Ton shackles on the squad. They are the older looking spring loaded twist style and are returning to Mike Green's trailer as they are his.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Nov 25, 2020 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 25, 2020
First and Last NameMister
Entry TypeGENERAL PASS ON
Your entry
A box of KN95 mask were delivered and placed in the Capt. office
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Tuesday, November 24, 2020

Nov 24, 2020 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 24, 2020
First and Last NameChief Ryman
Entry TypeGENERAL PASS ON
Your entry
Honda gen light is back and operating. Placed back on RS715.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Nov 24, 2020 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 23, 2020
First and Last Namekeefer
Entry TypeGENERAL PASS ON
Your entry
following picked up from small tools
2 chainsaw blades
2 dry chem
rs - rit regulator repaired
t - officer scba repaired
battery for tic
rs - tic dropped off for repair (loaner in sta)
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Monday, November 23, 2020

Nov 23, 2020 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 23, 2020
First and Last NameLyons
Entry TypeGENERAL PASS ON
Your entry
Engine sent out for DOT. Switched into RE-7. Equipment list follows...
All equipment on RE-7, including hard sleeves, nozzles and appliances, belongs to E715. The only exception is the ground ladders.
All the inch and a half hose belongs to E715.
Supply beds, 2 inch, 2 1/2 inch 3 inch hose all belong to RE-7.
Both crosslays are 200ft of 1 1/2". 400ft 1 1/2" 300ft 2" 250ft 2 1/2" off the rear

Saturday, November 21, 2020

Nov 21, 2020 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 21, 2020
First and Last NameChief Ryman
Entry TypeGENERAL PASS ON
Your entry
5 spare angle grinder blades and 3 spare band saw blades finally came in. Placed in tool box on RS715.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Nov 21, 2020 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateNov 20, 2020
First and Last NameMatt Adams
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITT715
Your entry
Truck 715 was called up to CMF to check on several items written up by B shift. The following occurred: CMF stated they mitigated the oil leak around the area of the power steering pump (new oil found on the floor A shift morning). There is a new fan blade assembly on order, and the issue causing the chipping has been fixed. CMF confirmed two air leaks involving the rear air bag and the leveling switch. Parts are on order to resolves both of those as well. CMF estimated a 1-2 week time frame and we are good to run it until then.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Friday, November 20, 2020

Nov 20, 2020 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 20, 2020
First and Last NameMatt Adams
Entry TypeGENERAL PASS ON
Your entry
Small Tools Miscellaneous- Cutter blade inserts replaced, new dry chem placed on E715, Loaner TIC placed on RS715.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Nov 20, 2020 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 20, 2020
First and Last NameMatt Adams
Entry TypeGENERAL PASS ON
Your entry
RS715s RIT pack regulator has a crack on the exterior housing. The regulator is still operable and we will attempt to get a replacement on Monday.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Nov 20, 2020 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateNov 20, 2020
First and Last NameMatt Adams
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITM715
Your entry
B-shift reported shifting issues between 3rd and 4th gear and it was reproduced on our first run. Medic unit was taking to CMF and the transmission was reset. So far no further issues.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Thursday, November 19, 2020

Nov 19, 2020 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateNov 19, 2020
First and Last NameChief Ryman
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITRS715 (E-ONE)
Your entry
The squad came back today. The following was supposed to be handled, if anything was not please let me know:
-The rear slide out swapped out to twice the rating and the shelving system reinforced. (It should be movable now and with plenty of capacity.)
-Check engine light fixed ( the issue was a bad DEF tank sensor)
-Both mirrors should now move appropriately.
-screws on exterior D handle door latches and the access panels in side the compartments were tighted and loc tited on all doors.
-Radio speakers in the cab were repositioned for additional view.
-All door sensors were adjusted. Mark had the driver's side belly compartment alarm once on the way back.
-The HAAS alert box was removed and sent for reprogrammed.
-Re-attach hand light charger in officer's seat
A road mechanic will be out to reinstall the HAAS box once updated, replace the paratech compartment interior door handle, and look at the sensor on the belly compartment again.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Nov 19, 2020 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateNov 19, 2020
First and Last NameRobert Marsh
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITPE715 (PIERCE)
Your entry
E4 Door wont open from inside of cab on Pierce Engine. Can be opened from outside. Will write up.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Nov 19, 2020 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 19, 2020
First and Last NameChief Ryman
Entry TypeGENERAL PASS ON
Your entry
RS715 honda gen light dropped off for warranty repair.
The loaner large enerpac pump, battery and charger were returned.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Wednesday, November 18, 2020

Nov 18, 2020 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 18, 2020
First and Last NameKitner
Entry TypeGENERAL PASS ON
Your entry
Technician was back out and confirmed hallway dryer still not drying - parts ordered will return when they ae in. Unknown ETA
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Nov 18, 2020 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateNov 18, 2020
First and Last NameChief Ryman
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITOTHER
OTHER UNIT
SPECIFY UNIT ID RRS1
Your entry
PTT for headsets on OIC side does not work. TSR submitted.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Monday, November 16, 2020

Nov 16, 2020 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateNov 16, 2020
First and Last NameRobert Marsh
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITRS715 (E-ONE)
Your entry
Switched into RRS1 so that New Rescue E One Rescue Squad can go to Patriot for Warranty work. We were instructed to take out all the cribbing in the back, leaving just one piece of each individual size in the compartment. Switch over list is saved to desktop on computer in watch office.
RRS1 = "A" Side of Hurst Pump not working properly. It took 30 seconds to open spreader on this side vs 15 seconds on Orange "B" Line. Written up. In order to power up Hurst pump you must turn on Breaker 21 in panel. You must also turn if off this way. Apparently on/off switch on pump is broken.
Two Air Bag Bags set up in walk in area. One complete set up for a 45 min cylinder (no threads) and One complete set up for a 60 min cylinder (threads).
Couldn't get Diesel Generator to stay running. Not concerned as half of the things it powers on this thing don't work.
If we are missing something you want, let me know. I can swing by patriot and bring it with me to work on Thursday.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Sunday, November 15, 2020

Nov 15, 2020 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 15, 2020
First and Last NameHiggins
Entry TypeGENERAL PASS ON
Your entry
There is not thermal imager on RS715 it was sent out on 11/13
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Nov 15, 2020 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 15, 2020
First and Last NameChief Ryman
Entry TypeGENERAL PASS ON
Your entry
The shoreline pig tail for the ambulance disappeared at some point during the day yesterday.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Nov 15, 2020 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateNov 15, 2020
First and Last NameChief Ryman
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITT715
Your entry
The following written up on T715 this morning. Some of them are duplicates of previous to remind CMF of outstanding issues:
-roto ray not working.
-rust forming on bottom and sides of turntable.
-steering needs alignment. unit pulls to the right.
-the back up alarm is not working (this was written up a few days ago but not put in the pass on).
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Saturday, November 14, 2020

Nov 14, 2020 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 14, 2020
First and Last NameChief Ryman
Entry TypeGENERAL PASS ON
Your entry
RS715-
Valve on the large Enerpac pump has been swapped out. New valve has the same positions as the old one, however it will lower without the pump being turned on.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Nov 14, 2020 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 14, 2020
First and Last NameChief Ryman
Entry TypeGENERAL PASS ON
Your entry
RS715 front winch controller placed in waterproof pelican case and located in the winch compartment.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Friday, November 13, 2020

Nov 13, 2020 - APPLIANCE DEFECT

Your form has a new entry.

Here are the results.

DateNov 13, 2020
First and Last NameSmo
Entry TypeAPPLIANCE DEFECT
Your entry
Genesis battery-powered hydraulic cutter C-236 blade inserts are shot. This is causing the tool to struggle to make cuts and causing the tool to twist on the simplest cuts. I'm told small tools has replacement inserts, ticket written.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Nov 13, 2020 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 13, 2020
First and Last NameSmo
Entry TypeGENERAL PASS ON
Your entry
Vendor Returned both Lifting Cylinder pumps. Pumps placed in service back on the RS.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Nov 13, 2020 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 13, 2020
First and Last NameSmo
Entry TypeGENERAL PASS ON
Your entry
Atlantic came out to the station to address the leaking fluid from the portable hydraulic pump on the RS. He found two out of the three hydraulic pig tails required new male fittings. He replaced the fittings which corrected the leak that was occurring. Should be good to go moving forward.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Thursday, November 12, 2020

Nov 12, 2020 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 12, 2020
First and Last NameKitner
Entry TypeGENERAL PASS ON
Your entry
Common Frig was not cooling, temperature was up to 54* repair man found leak and repaired. Frig is now cooling but most everything in it was tossed due to being over 50*
New Coffee Carafe arrived, you need to tilt it to the side when placing under filter bin.
M715 back in service
Truck 15 frayed brake line repaired at CMF
Hallway dryer written up again due to not heating.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Wednesday, November 11, 2020

Nov 11, 2020 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 11, 2020
First and Last NameChief Ryman
Entry TypeGENERAL PASS ON
Your entry
RS715
Replacement metal handle knob installed on battery cutter.
200" bag of utility rope is now in rope compartment.
**Please watch out when opening paratech compartment with plymovent attached. If you do that and pull out the paratech tip tray, the tray will smash into the end of the door on the way back in from pressure applied by the plymovent.**
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

EMS Advancement - EMT Alexis Smith Driver Status



BVFD Team -


Please join the BVFD Officers in congratulating EMT Alexis Smith on becoming our latest EMS Unit Driver!!

Alexis joined the BVFD in July of 2016 and has been consistently taking training classes to earn her status as EMT in Charge and now as an Emergency EMS Driver.  Alexis completed EVOC, then began working through the BVFD cognitive and practical examinations (on our Ambulance, emergency laws, area streets, and hospital running routes). The final training phase required her to demonstrate proficiency driving on numerous emergency calls under the evaluation of an experienced Driver. Alexis drove on a wide variety of emergency calls, including hospital transports to meet the final requirements and earn Emergency Driver status. The BVFD salutes her hard work and constant dedication. 

We salute EMT Smith for her dedication and commitment to serving others, especially during a national pandemic.


Chief Ryman and I salute all of the BVFD personnel who have consistently provided vital staffing throughout the pandemic.  Keep up the amazing work!  






For COVID-19 Information and resources, visit: www.montgomerycountymd.gov/COVID19

Tuesday, November 10, 2020

Nov 10, 2020 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 10, 2020
First and Last NameChief Ryman
Entry TypeGENERAL PASS ON
Your entry
RS equipment stuff:
Paratech picked up broken hydrafusion and provided a loaner.
Hydrafusion pumps topped off with fluid. One bottle of spare fluid in the flammable liquid cabinet.
Genesis portable pump is having coupling issues with adapters for hoses. Either hook up adapters with pump totally off, or hook up the male end of the adapter first, otherwise fluid sprays out. The vendor will be out on Friday to handle.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Nov 10, 2020 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 10, 2020
First and Last NameMark Grant
Entry TypeGENERAL PASS ON
Your entry
Squad Driver and Officer SCBA back from SCBA shop, placed on squad.
Spare 4 returned from SCBA shop and placed in shop.

Nov 10, 2020 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 10, 2020
First and Last NameMark Grant
Entry TypeGENERAL PASS ON
Your entry
Squad plymovent repaired and returned to service.

Monday, November 9, 2020

Nov 09, 2020 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateNov 09, 2020
First and Last NameJason Eberly
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITRS715 (E-ONE)
OTHER UNIT
SPECIFY UNIT ID RS715 (E-One)
Your entry
Genesis battery powered hydraulic cutter C-236 plastic locking knob on handle is broken
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Sunday, November 8, 2020

Nov 08, 2020 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 07, 2020
First and Last NameRobert Marsh
Entry TypeGENERAL PASS ON
Your entry
Rescue Squad 715:
Chain compartment organized. On the tray that holds all the straight chain, the 3/8ths is on the front and the 9/32nds is on the back. There is one 30 Foot piece of 3/8ths on the back that wouldn't fit on the front. The longest lengths go in the back and the shorter lengths go in the front. The bins are labeled as well.
We added labels to the winch's that designate the length and strength as well
Both Winch controllers are now located under the drivers seat.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Friday, November 6, 2020

Nov 06, 2020 - APPARATUS DEFECT

Your form has a new entry.

Here are the results.

DateNov 06, 2020
First and Last NameWillie O
Entry TypeAPPARATUS DEFECT
APPARATUS DEFECT
UNITPE715 (PIERCE)
Your entry
Power steering fluid level alarm has been disconnected and reported to CMF.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Nov 06, 2020 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 06, 2020
First and Last NameChief Ryman
Entry TypeGENERAL PASS ON
Your entry
Rs715 front winch hook replaced. New hook is rated for 15K.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Wednesday, November 4, 2020

Nov 04, 2020 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 04, 2020
First and Last NameChief Ryman
Entry TypeGENERAL PASS ON
Your entry
CMF picked up the Pierce squad to handle some minor repairs that have been neglected since March. It will be back this week, but will remain unavailable as a reserve and has been removed from county maintenance.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Tuesday, November 3, 2020

Nov 03, 2020 - APPLIANCE DEFECT

Your form has a new entry.

Here are the results.

DateNov 03, 2020
First and Last Namemiller
Entry TypeAPPLIANCE DEFECT
Your entry
cutters edge was taken off of T715, pull cord unspoiled and was retention. Saw was placed in the shop.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Nov 03, 2020 - STATION DEFECT

Your form has a new entry.

Here are the results.

DateNov 03, 2020
First and Last NameChief Ryman
Entry TypeSTATION DEFECT
Your entry
Retractor is not working on RS715 plymovent.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Nov 03, 2020 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 03, 2020
First and Last NameChief Ryman
Entry TypeGENERAL PASS ON
Your entry
Damaged 610 shore from RS715 is back in-service. Paratech was okay with the burred area being filed down.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Monday, November 2, 2020

Nov 02, 2020 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 02, 2020
First and Last NameCaptain Clemens
Entry TypeGENERAL PASS ON
Your entry
The big white cylinder for the meter calibration was expired and changed by Goyette.
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Nov 02, 2020 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 02, 2020
First and Last NameCaptain Clemens
Entry TypeGENERAL PASS ON
Your entry
B715 hose testing one section 1" one section 3" failed. Both replaced by Small Tools today
IF DEFECT, WAS A REPAIR REQUEST MADE?YES

Nov 02, 2020 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 02, 2020
First and Last NameCaptain Clemens
Entry TypeGENERAL PASS ON
Your entry
M715 getting DOT running RA20
IF DEFECT, WAS A REPAIR REQUEST MADE?NO

Extra enerpac pump

This pump and battery are not ours. I'm working with Enerpac on return. Please don't damage them. 



Michael Ryman
Fire Chief
Burtonsville VFD 
570-766-9054 




For COVID-19 Information and resources, visit: www.montgomerycountymd.gov/COVID19

Sunday, November 1, 2020

Nov 01, 2020 - GENERAL PASS ON

Your form has a new entry.

Here are the results.

DateNov 01, 2020
First and Last NameChief Ryman
Entry TypeGENERAL PASS ON
Your entry
1 hydrafusion shore OOS. 1 610 longshore strut has a gouge in the end. I will contact paratech tomorrow about status. Please don't use until then.
IF DEFECT, WAS A REPAIR REQUEST MADE?YES